Your browser doesn't support javascript.
loading
Analytical validation of an enzyme-linked immunosorbent assay for the quantification of S100A12 in the serum and feces of cats.
Bridges, Cory S; Grützner, Niels; Suchodolski, Jan S; Steiner, Jörg M; Heilmann, Romy M.
Affiliation
  • Bridges CS; Gastrointestinal Laboratory, Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA.
  • Grützner N; Institute of Agricultural and Nutritional Sciences, Martin Luther University Halle-Wittenberg, Halle (Saale), SA, Germany.
  • Suchodolski JS; Gastrointestinal Laboratory, Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA.
  • Steiner JM; Gastrointestinal Laboratory, Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA.
  • Heilmann RM; Department for Small Animals, Veterinary Teaching Hospital, College of Veterinary Medicine, University of Leipzig, Leipzig, SN, Germany.
Vet Clin Pathol ; 48(4): 754-761, 2019 Dec.
Article in En | MEDLINE | ID: mdl-31820477
ABSTRACT

BACKGROUND:

Measuring S100A12 concentrations in serum and feces is a sensitive and specific marker of inflammation, such as seen with chronic gastrointestinal inflammation in people and dogs. Biomarkers of inflammation in cats are currently lacking.

OBJECTIVES:

We aimed to analytically cross-validate the canine S100A12-ELISA for the measurement of S100A12 in feline specimens.

METHODS:

The ELISA was analytically validated by assessing dilutional linearity, spiking/recovery, intra- and inter-assay variability. Reference intervals for serum and fecal feline S100A12 concentrations were calculated using samples from healthy cats, and the short-term biological variation of fecal S100A12 was assessed.

RESULTS:

Observed-to-expected ratios (O/E) for serial dilutions of serum and fecal extracts ranged from 91%-159% (mean, 120%) and 100%-128% (mean, 114%), and for the spiking/recovery method ranged from 106%-263% (mean, 154%) and 52%-171% (mean, 112%). Intra- and inter-assay CV% for serum were ≤5.6% and ≤14.0%, and for fecal extracts were ≤3.8% and ≤19.1%, repsectively. RIs for feline serum and fecal S100A12 concentrations were <43 µg/L and < 20 ng/g, respectively. A mild short-term biologic variation, but large individuality were detected when measuring fecal S100A12 concentrations in healthy cats.

CONCLUSIONS:

The canine S100A12-ELISA is accurate, reproducible, and sufficiently linear and precise for the measurement of S100A12 in feline serum and fecal samples. The use of this assay is a reasonable option for the measurement of S100A12 concentrations in feline specimens and provides a basis for the further evaluation of  S100A12 in cats with gastrointestinal disease. Using a population-based RI for fecal feline S100A12 appears to be of limited value.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Enzyme-Linked Immunosorbent Assay / Cats / S100A12 Protein Limits: Animals Language: En Journal: Vet Clin Pathol Journal subject: MEDICINA VETERINARIA / PATOLOGIA Year: 2019 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Enzyme-Linked Immunosorbent Assay / Cats / S100A12 Protein Limits: Animals Language: En Journal: Vet Clin Pathol Journal subject: MEDICINA VETERINARIA / PATOLOGIA Year: 2019 Document type: Article Affiliation country: Estados Unidos