Your browser doesn't support javascript.
loading
Hepatic steatosis assessment using ultrasound homodyned-K parametric imaging: the effects of estimators.
Zhou, Zhuhuang; Zhang, Qiyu; Wu, Weiwei; Lin, Ying-Hsiu; Tai, Dar-In; Tseng, Jeng-Hwei; Lin, Yi-Ru; Wu, Shuicai; Tsui, Po-Hsiang.
Affiliation
  • Zhou Z; College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
  • Zhang Q; College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
  • Wu W; College of Biomedical Engineering, Capital Medical University, Beijing 100069, China.
  • Lin YH; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
  • Tai DI; Department of Gastroenterology and Hepatology, Chang Gung Memorial Hospital at Linkou, Chang Gung University, Taoyuan 33302, Taiwan.
  • Tseng JH; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan 33302, Taiwan.
  • Lin YR; Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
  • Wu S; College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China.
  • Tsui PH; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan.
Quant Imaging Med Surg ; 9(12): 1932-1947, 2019 Dec.
Article in En | MEDLINE | ID: mdl-31929966
ABSTRACT

BACKGROUND:

The homodyned-K (HK) distribution is an important statistical model for describing ultrasound backscatter envelope statistics. HK parametric imaging has shown potential for characterizing hepatic steatosis. However, the feasibility of HK parametric imaging in assessing human hepatic steatosis in vivo remains unclear.

METHODS:

In this paper, ultrasound HK µ parametric imaging was proposed for assessing human hepatic steatosis in vivo. Two recent estimators for the HK model, RSK (the level-curve method that uses the signal-to-noise ratio (SNR), skewness, and kurtosis based on the fractional moments of the envelope) and XU (the estimation method based on the first moment of the intensity and two log-moments, namely X- and U-statistics), were investigated. Liver donors (n=72) and patients (n=204) were recruited to evaluate hepatic fat fractions (HFFs) using magnetic resonance spectroscopy and to evaluate the stages of fatty liver disease (normal, mild, moderate, and severe) using liver biopsy with histopathology. Livers were scanned using a 3-MHz ultrasound to construct µ RSK and µ XU images to correlate with HFF analyses and fatty liver stages. The µ RSK and µ XU parametric images were constructed using the sliding window technique with the window side length (WSL) =1-9 pulse lengths (PLs). The diagnostic values of the µ RSK and µ XU parametric imaging methods were evaluated using receiver operating characteristic (ROC) curves.

RESULTS:

For the 72 participants in Group A, the µ RSK parametric imaging with WSL =2-9 PLs exhibited similar correlation with log10(HFF), and the µ RSK parametric imaging with WSL = 3 PLs had the highest correlation with log10(HFF) (r=0.592); the µ XU parametric imaging with WSL =1-9 PLs exhibited similar correlation with log10(HFF), and the µ XU parametric imaging with WSL =1 PL had the highest correlation with log10(HFF) (r=0.628). For the 204 patients in Group B, the areas under the ROC (AUROCs) obtained using µ RSK for fatty stages ≥ mild (AUROC1), ≥ moderate (AUROC2), and ≥ severe (AUROC3) were (AUROC1, AUROC2, AUROC3) = (0.56, 0.57, 0.53), (0.68, 0.72, 0.75), (0.73, 0.78, 0.80), (0.74, 0.77, 0.79), (0.74, 0.78, 0.79), (0.75, 0.80, 0.82), (0.74, 0.77, 0.83), (0.74, 0.78, 0.84) and (0.73, 0.76, 0.83) for WSL =1, 2, 3, 4, 5, 6, 7, 8 and 9 PLs, respectively. The AUROCs obtained using µ XU for fatty stages ≥ mild, ≥ moderate, and ≥ severe were (AUROC1, AUROC2, AUROC3) = (0.75, 0.83, 0.81), (0.74, 0.80, 0.80), (0.76, 0.82, 0.82), (0.74, 0.80, 0.84), (0.76, 0.80, 0.83), (0.75, 0.80, 0.84), (0.75, 0.79, 0.85), (0.75, 0.80, 0.85) and (0.73, 0.77, 0.83) for WSL = 1, 2, 3, 4, 5, 6, 7, 8 and 9 PLs, respectively.

CONCLUSIONS:

Both the µ RSK and µ XU parametric images are feasible for evaluating human hepatic steatosis. The WSL exhibits little impact on the diagnosing performance of the µ RSK and µ XU parametric imaging. The µ XU parametric imaging provided improved performance compared to the µ RSK parametric imaging in characterizing human hepatic steatosis in vivo.