Your browser doesn't support javascript.
loading
C-Elastography: In Vitro Feasibility Phantom Study.
Shahraki, Danial P; Kumar, Viksit; Ghavami, Siavash; Urban, Matthew W; Alizad, Azra; Guzina, Bojan B; Fatemi, Mostafa.
Affiliation
  • Shahraki DP; Department of Civil, Environmental and Geo-Engineering, University of Minnesota, Twin Cities, Minnesota, USA.
  • Kumar V; Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine & Science, Rochester, Minnesota, USA.
  • Ghavami S; Department of Radiology, Mayo Clinic College of Medicine & Science, Rochester, Minnesota, USA.
  • Urban MW; Department of Radiology, Mayo Clinic College of Medicine & Science, Rochester, Minnesota, USA.
  • Alizad A; Department of Radiology, Mayo Clinic College of Medicine & Science, Rochester, Minnesota, USA.
  • Guzina BB; Department of Civil, Environmental and Geo-Engineering, University of Minnesota, Twin Cities, Minnesota, USA. Electronic address: guzin001@umn.edu.
  • Fatemi M; Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine & Science, Rochester, Minnesota, USA.
Ultrasound Med Biol ; 46(7): 1738-1754, 2020 07.
Article in En | MEDLINE | ID: mdl-32312548
ABSTRACT
C-Elastography (CE) is a new ultrasound technique that locally maps the non-linear elasticity of soft tissue using low-frequency (150-250 Hz) shear waves generated by the acoustic radiation force (ARF). CE is based on a recent finding that the magnitude of the ARF in an isotropic tissue-like solid is related linearly to a third-order modulus of elasticity, C, which is responsible for the coupling between deviatoric and volumetric constitutive behaviors. The main objective of the work described here was to examine the feasibility of using and performance of C-elastography in differentiating and characterizing soft tissue via a pilot study on ex vivo tissue and tissue-mimicking inclusions cast in a gelatin block. In this vein, the CE technique deploys a combination of ultrasound motion sensing and 3-D visco-elastodynamic simulation to estimate the non-linear modulus C. As ultrasound focusing inherently confines the ARF to a small region, CE provides the means for measuring C within O(mm3) volumes. Equipped with such data analysis, we performed in vitro CE experiments on agar-based, xenograft and normal breast tissue samples embedded in a gelatin matrix. The compound C-elastograms indicate marked (and sharp) C-contrast, with average values of 1.9 and 5.6 at push points inside the featured soft and hard inclusions, respectively.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Elasticity Imaging Techniques Type of study: Diagnostic_studies Limits: Female / Humans Language: En Journal: Ultrasound Med Biol Year: 2020 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Elasticity Imaging Techniques Type of study: Diagnostic_studies Limits: Female / Humans Language: En Journal: Ultrasound Med Biol Year: 2020 Document type: Article Affiliation country: Estados Unidos