Detection of glucosylsphingosine in dried blood spots for diagnosis of Gaucher disease by LC-MS/MS.
Clin Biochem
; 87: 79-84, 2021 Jan.
Article
in En
| MEDLINE
| ID: mdl-33188770
INTRODUCTION: Gaucher disease (GD) is caused by a deficiency of ß-glucosidase (GCase), leading to accumulation of glucosylceramide (GlcC) and glucosylsphingosine (Lyso-Gb1). Lyso-Gb1 is a reliable biomarker for GD. OBJECTIVES: This study aims to develop a simple, effective and accurate method for the screening and diagnosis of GD using dried blood spot (DBS) samples. METHODS: Lyso-Gb1 in DBS was extracted by 50% acetonitrile aqueous solution containing isotope-labeled internal standard and analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS). A reference interval was established by analyzing samples from 277 healthy controls. Lyso-Gb1 was detected in the residual DBS samples from 142 high-risk patients with splenomegaly and/or thrombocytopenia. Based on GCase activity in DBS, samples were classified into four groups: confirmed GD patients (n = 52), GD carriers (n = 5), false positive (n = 36) and negative (n = 49). RESULTS: The optimized Lyso-Gb1 assay showed intra- and inter-assay variations ranged between 2.0%-8.2% and 3.8%-10.2%, respectively. Accuracies ranged from 93.5% to 112.6%. The lowest limit of quantification was 1 ng/mL. The normal reference interval of Lyso-Gb1 in DBS ranged from 2.1 to 9.9 ng/mL. Among the 142 subjects, except for one GD patient (Lyso-Gb1 > 2500 ng/mL), the Lyso-Gb1 concentrations in 51 GD patients ranged from 190.5 to 2380.6 ng/mL (the median 614.8 ng/mL). Also, one negative patient was found to have an elevated Lyso-Gb1 level (684.5 ng/mL), while the other patients were normal. The negative case was then confirmed to be an atypical GD patient with a c.1091A > G (p.Y364C) homozygous variant in PSAP gene by next generation sequencing. CONCLUSIONS: The optimized method to determine Lyso-Gb1 in DBS was demonstrated as a useful tool for the screening and diagnosis of GD.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Psychosine
/
Chromatography, Liquid
/
Tandem Mass Spectrometry
/
Dried Blood Spot Testing
/
Gaucher Disease
Type of study:
Diagnostic_studies
/
Observational_studies
/
Risk_factors_studies
Limits:
Adolescent
/
Adult
/
Child
/
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
/
Middle aged
/
Newborn
Language:
En
Journal:
Clin Biochem
Year:
2021
Document type:
Article
Affiliation country:
China
Country of publication:
Estados Unidos