Your browser doesn't support javascript.
loading
Systematic Approach to High Implantation of SAPIEN-3 Valve Achieves a Lower Rate of Conduction Abnormalities Including Pacemaker Implantation.
Sammour, Yasser; Banerjee, Kinjal; Kumar, Arnav; Lak, Hassan; Chawla, Sanchit; Incognito, Cameron; Patel, Jay; Kaur, Manpreet; Abdelfattah, Omar; Svensson, Lars G; Tuzcu, E Murat; Reed, Grant W; Puri, Rishi; Yun, James; Krishnaswamy, Amar; Kapadia, Samir.
Affiliation
  • Sammour Y; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Banerjee K; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Kumar A; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Lak H; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Chawla S; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Incognito C; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Patel J; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Kaur M; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Abdelfattah O; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Svensson LG; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Tuzcu EM; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Reed GW; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Puri R; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Yun J; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Krishnaswamy A; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
  • Kapadia S; Heart and Vascular Institute, Cleveland Clinic Foundation, OH.
Circ Cardiovasc Interv ; 14(1): e009407, 2021 01.
Article in En | MEDLINE | ID: mdl-33430603
ABSTRACT

BACKGROUND:

The conventional method of implanting balloon-expandable SAPIEN-3 (S3) valve results in a final 7030 or 8020 ratio of the valve in the aortaleft ventricular outflow tract with published rates of permanent pacemaker around 10%. We sought to evaluate whether higher implantation of S3 reduces conduction abnormalities including the need for permanent pacemaker.

METHODS:

We included consecutive patients who underwent transfemoral transcatheter aortic valve replacement using S3 between April 2015 and December 2018 and compared outcomes with typical valve deployment strategy to our more contemporary high deployment technique (HDT). We excluded patients with nontransfemoral access or valve-in-valve.

RESULTS:

Among 1028 patients, HDT was performed in 406 patients (39.5%). Mean implantation depth under the noncoronary cusp was significantly smaller with HDT compared with conventional technique (1.5±1.6 versus 3.2±1.9 mm; P<0.001). Successful implantation was achieved in 100% of the patients in both groups with no cases of conversion to open heart surgery, second valve implantation within the first transcatheter aortic valve replacement, or coronary occlusion during transcatheter aortic valve replacement. One patient (0.2%) had valve embolization with HDT (P=0.216). Thirty-day permanent pacemaker rates were lower with HDT (5.5% versus 13.1%; P<0.001), as were rates of complete heart block (3.5% versus 11.2%; P<0.001) and new-onset left bundle branch block (5.3% versus 12.2%; P<0.001). There were no differences in mild (16.5% versus 15.9%; P=0.804), or moderate-to-severe aortic regurgitation (1% versus 2.7%; P=0.081) at 1 year. HDT was associated with slightly higher 1-year mean gradients (13.1±6.2 versus 11.8±4.9 mm Hg; P=0.042) and peak gradients (25±11.9 versus 22.5±9 mm Hg; P=0.026). However, Doppler velocity index was similar (0.47±0.15 versus 0.48±0.13; P=0.772).

CONCLUSIONS:

Our novel technique for balloon-expandable S3 valve positioning consistently achieves higher implantation resulting in substantial reduction in conduction abnormalities and permanent pacemaker requirement after transcatheter aortic valve replacement without compromising procedural safety or valve hemodynamics. Operators should consider this as an important technique to improve patient outcomes.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Pacemaker, Artificial / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Limits: Humans Language: En Journal: Circ Cardiovasc Interv Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2021 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Pacemaker, Artificial / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Limits: Humans Language: En Journal: Circ Cardiovasc Interv Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2021 Document type: Article