Semi-quantitative scoring of imaging modalities in detecting soft tissue foreign bodies: an in vitro study.
Alfuraih, Abdulrahman M; Almutairi, Faisal N; Alotaibi, Sultan B; Alshmrani, Abdullah A.
Affiliation
  • Alfuraih AM; Radiology and Medical Imaging Department, College of Applied Medical Sciences, 204568Prince Sattam bin Abdulaziz University, Kharj, Saudi Arabia.
  • Almutairi FN; Radiology and Medical Imaging Department, College of Applied Medical Sciences, 204568Prince Sattam bin Abdulaziz University, Kharj, Saudi Arabia.
  • Alotaibi SB; Radiology and Medical Imaging Department, College of Applied Medical Sciences, 204568Prince Sattam bin Abdulaziz University, Kharj, Saudi Arabia.
  • Alshmrani AA; Radiology and Medical Imaging Department, College of Applied Medical Sciences, 204568Prince Sattam bin Abdulaziz University, Kharj, Saudi Arabia.
Acta Radiol ; 63(4): 474-480, 2022 Apr.
Article in En | MEDLINE | ID: mdl-33673754
ABSTRACT

BACKGROUND:

Accurate identification of foreign bodies (FB) using medical imaging is essential for diagnosis and determining the suitable retrieval technique.

PURPOSE:

To compare the sensitivity of different imaging modalities for detecting various FB materials in soft tissue and assess the reproducibility of a scoring system for grading the conspicuity of FBs. MATERIAL AND

METHODS:

Five FB materials (plastic, wood, glass, aluminum, and copper) were embedded in a tissue-mimicking phantom. Computed radiography (CR), ultrasound, computed tomography (CT), and magnetic resonance imaging (MRI) were compared using a semi-quantitative 5-point Likert scale scoring system. The intra- and inter-reader reproducibility of four independent readers was analyzed using Kendall's coefficient of concordance (W).

RESULTS:

Glass was visible on all imaging modalities. Plastic was only visible in excellent detail using ultrasound. Wood was detected in excellent resolution using ultrasound and CT using the default window while plain X-ray failed to detect it. Ultrasound was the only modality that showed aluminum in excellent quality while CT showed it with good demarcation from the surroundings. Copper was detectable in excellent detail using CR, ultrasound, and CT. MRI performance was suboptimal, especially with the plastic FB. The scoring system showed excellent intra-reader (W = 0.91, P = 0.001) and inter-reader (W = 0.88, P < 0.001) reproducibility.

CONCLUSION:

Ultrasound can be used as the first line of investigation for wood, plastic, glass, and metallic FBs impacted at superficial depths in soft tissue. The semi-quantitative FB scoring system showed excellent within- and between-reader reliability, which can be used to score and compare the detection performance of new imaging techniques.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Diagnostic Imaging / Soft Tissue Injuries / Phantoms, Imaging / Foreign Bodies Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: Acta Radiol Year: 2022 Document type: Article Affiliation country: Arabia Saudita

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Diagnostic Imaging / Soft Tissue Injuries / Phantoms, Imaging / Foreign Bodies Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: Acta Radiol Year: 2022 Document type: Article Affiliation country: Arabia Saudita
...