Your browser doesn't support javascript.
loading
A novel algorithm for extracting soft-tissue and bone images measured using a photon-counting type X-ray imaging detector with the help of effective atomic number analysis.
Kimoto, Natsumi; Hayashi, Hiroaki; Lee, Cheonghae; Maeda, Tatsuya; Ando, Miku; Kanazawa, Yuki; Katsumata, Akitoshi; Yamamoto, Shuichiro; Okada, Masahiro.
Affiliation
  • Kimoto N; College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Ishikawa, 920-0942, Japan. Electronic address: natsumi.kimoto.0717@gmail.com.
  • Hayashi H; College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Ishikawa, 920-0942, Japan. Electronic address: hayashi.hiroaki@staff.kanazawa-u.ac.jp.
  • Lee C; Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan. Electronic address: lee.cheonghae.1999@gmail.com.
  • Maeda T; Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan. Electronic address: tatsuya.maeda.1108@gmail.com.
  • Ando M; School of Health Sciences, Kanazawa University, Ishikawa, 920-0942, Japan. Electronic address: ando.miku.1999@gmail.com.
  • Kanazawa Y; Graduate School of Biomedical Sciences, Tokushima University, Tokushima, 770-8503, Japan. Electronic address: yk@tokushima-u.ac.jp.
  • Katsumata A; Department of Oral Radiology, Asahi University, Gifu, 501-0223, Japan. Electronic address: kawamata@dent.asahi-u.ac.jp.
  • Yamamoto S; JOB CORPORATION, Kanagawa, 222-0033, Japan. Electronic address: s.yamamoto@job-image.com.
  • Okada M; JOB CORPORATION, Kanagawa, 222-0033, Japan. Electronic address: maple@mth.biglobe.ne.jp.
Appl Radiat Isot ; 176: 109822, 2021 Oct.
Article in En | MEDLINE | ID: mdl-34256271
ABSTRACT
Most of the objects targeted for X-ray examination are composed of soft-tissue and bone. We aimed to develop an algorithm for generating X-ray images which can give quantitative information of soft-tissue and bone using an energy-resolving photon-counting type imaging detector. We used polychromatic X-rays for analysis in which both the beam hardening effect and detector response were properly corrected and then succeeded in virtually treating the amount of measured X-ray attenuation as if it were measured using monochromatic X-rays.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone and Bones / Algorithms / Connective Tissue Type of study: Prognostic_studies Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2021 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone and Bones / Algorithms / Connective Tissue Type of study: Prognostic_studies Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2021 Document type: Article