Your browser doesn't support javascript.
loading
Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study.
Khandagale, Pooja D; Shetty, Prashant P; Makandar, Saleem D; Bapna, Pradeep A; Karobari, Mohmed Isaqali; Marya, Anand; Messina, Pietro; Scardina, Giuseppe Alessandro.
Affiliation
  • Khandagale PD; Department of Conservative Dentistry and Endodontics, Pacific Dental College and Hospital, Udaipur, Rajasthan, India.
  • Shetty PP; Department of Conservative Dentistry and Endodontics, Pacific Dental College, Debari, Udaipur 313024, India.
  • Makandar SD; Conservative Dentistry Unit, School of Dental Sciences, Universiti Sains Malaysia, Health Campus, 16150 Kubang Kerian, Kota Bharu, Kelantan, Malaysia.
  • Bapna PA; Department of Conservative Dentistry and Endodontics, Pacific Dental College, Debari, Udaipur 313024, India.
  • Karobari MI; Conservative Dentistry Unit, School of Dental Sciences, Universiti Sains Malaysia, Health Campus, 16150 Kubang Kerian, Kota Bharu, Kelantan, Malaysia.
  • Marya A; Department of Conservative Dentistry & Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences University, Chennai 600077, Tamil Nadu, India.
  • Messina P; Department of Orthodontics, Faculty of Dentistry, University of Puthisastra, Phnom Penh, Cambodia.
  • Scardina GA; Department of Surgical Oncological and Stomatological Disciplines, University of Palermo, Palermo, Italy.
Int J Dent ; 2021: 7402658, 2021.
Article in En | MEDLINE | ID: mdl-34367289
INTRODUCTION: The main aims of root canal instrumentation are to provide an environment that will lead to healing and to provide a root canal shape that is comfortable to clean and seal. When working with rotary endodontic instruments, the most significant concerns are that the instrument might fracture in the root canal, thus affecting the treatment outcome. Hence, it is of immense importance to know which file systems have more cyclic fatigue resistance. Methodology. This study evaluated the effect of the curved segment length of the artificial canal (the arch), and the number of cycles necessary in fracture of Hyflex EDM, Twisted files, and ProTaper Gold were recorded. Sixty NiTi rotary instruments of 25 mm length (Hyflex EDM (20), Twisted files (20), and ProTaper Gold (20)) were tested in a metal block with simulated canal having 90° angle of curvature. The study was performed with a specific radius and degree of curvature, i.e., 8 mm radius and 90° angle of curvature, and data obtained were subsequently subjected to statistical evaluation using one-way analysis of variance and Tukey's post hoc test. RESULT: The Hyflex EDM (774.29) exhibited the maximum cyclic fatigue resistance compared to Twisted files (654.875) and ProTaper Gold (375.575). A statistically significant difference was observed between the tested groups. CONCLUSION: The Hyflex EDM files showed the highest cyclic fatigue resistance, followed by Twisted files and ProTaper Gold files.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Dent Year: 2021 Document type: Article Affiliation country: India Country of publication: Egipto

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Int J Dent Year: 2021 Document type: Article Affiliation country: India Country of publication: Egipto