Your browser doesn't support javascript.
loading
A novel biosensing system for rapid and sensitive detection of heavy metal toxicity in water.
Ngoc, Le Thi Bao; Linh, Duong Nhat; Van Minh, Nguyen; Duy, Nguyen Phuc Hoang; Phuong, Pham Thi Thuy.
Affiliation
  • Ngoc LTB; University of Science, 227 Nguyen Van Cu Street, District 5, Ho Chi Minh City, Vietnam; Vietnam National University, Linh Trung Ward, Thu Duc District, Ho Chi Minh City, Vietnam; Institute of Chemical Technology - Vietnam Academy of Science and Technology, 1A TL29 Street, Thanh Loc Ward, District 12
  • Linh DN; Ho Chi Minh City Open University, 97 Vo Van Tan Street, District 3, Ho Chi Minh City, Vietnam.
  • Van Minh N; Ho Chi Minh City Open University, 97 Vo Van Tan Street, District 3, Ho Chi Minh City, Vietnam.
  • Duy NPH; Institute of Chemical Technology - Vietnam Academy of Science and Technology, 1A TL29 Street, Thanh Loc Ward, District 12, Ho Chi Minh City, Vietnam.
  • Phuong PTT; Institute of Chemical Technology - Vietnam Academy of Science and Technology, 1A TL29 Street, Thanh Loc Ward, District 12, Ho Chi Minh City, Vietnam; Graduate University of Science and Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet Street, Cau Giay District, Hanoi, Vietnam
J Hazard Mater ; 416: 126123, 2021 08 15.
Article in En | MEDLINE | ID: mdl-34492917
Toxicity biosensors have recently gained significant attention due to their potential use in online monitoring. However, the effects of toxicants and the influence of dose, exposure time, and type and concentration of respiration substrate (RS) on the performance of a bioreactor are species-specific. Although these factors need to be investigated case-by-case as they can lead either to damage or self-repair of the affected microorganisms, they have seldom been considered in previous studies. Therefore, this work examined, for the first time, the effects of resting time and RS concentration on the performance of the biosensing system for toxicity of Cr6+ in water. In addition, it is also the first time that a novel non-contact fluid delivery system was applied to a toxicity biosensing system to prevent unstable responses. By choosing the best RS concentration and balancing the resting and exposure times, the proposed procedure exhibits promising results in terms of minimum detectable concentration (MDC), limit of detection (LOD), detection range, linearity, sensitivity, reproducibility and accuracy. The recovery time was only a few hours and the coefficients of variation of inhibition and recovery were only 12% and 9.6%, respectively, during six times reuse over one month of storage.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Metals, Heavy Type of study: Diagnostic_studies Limits: Humans Language: En Journal: J Hazard Mater Journal subject: SAUDE AMBIENTAL Year: 2021 Document type: Article Country of publication: Países Bajos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Metals, Heavy Type of study: Diagnostic_studies Limits: Humans Language: En Journal: J Hazard Mater Journal subject: SAUDE AMBIENTAL Year: 2021 Document type: Article Country of publication: Países Bajos