Your browser doesn't support javascript.
loading
A sensitive fluorescence "turn on" nanosensor for glutathione detection based on Ce-MOF and gold nanoparticles.
Gong, Congcong; Li, Zhijian; Liu, Gang; Wang, Renjie; Pu, Shouzhi.
Affiliation
  • Gong C; Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China.
  • Li Z; Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China. Electronic address: 15110740008@fudan.edu.cn.
  • Liu G; Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China.
  • Wang R; Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China.
  • Pu S; Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China; YuZhang Normal University, Nanchang 330013, PR China. Electronic address: pushouzhi@tsinghua.org.cn.
Spectrochim Acta A Mol Biomol Spectrosc ; 265: 120362, 2022 Jan 15.
Article in En | MEDLINE | ID: mdl-34509887
ABSTRACT
Glutathione (GSH) as an essential biothiol maintains redox homeostasis in human body, the aberrant level of it has been related to various diseases. In this work, we constructed a facile and environment-friendly strategy by using Ce based metal-organic frameworks and gold nanoparticles (AuNPs) for detection of GSH. The fluorescence intensity of the Ce-MOF was quenched by AuNPs, which is ascribed to the existence of fluorescence resonance energy transfer (FRET) and electrostatic interaction between Ce-MOFs and AuNPS. Because of the formation of Au-SH between AuNPs and GSH, the addition GSH induced the Ce-MOF/AuNPs and prevented the occurrence of FRET and electrostatic interaction between Ce-MOFs and AuNPS, which futher recovered the fluorescence of Ce-MOF. Under the optimized conditions, this "turn-on" sensing process revealed a high selectivity toward GSH and displayed good linearity in range of 0.2-32.5 µM with low detection limit of 58 nM. In addition, the practicability of the strategy was testified through analyzing GSH in real human serum samples.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Metal Nanoparticles / Gold Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Spectrochim Acta A Mol Biomol Spectrosc Journal subject: BIOLOGIA MOLECULAR Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Metal Nanoparticles / Gold Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Spectrochim Acta A Mol Biomol Spectrosc Journal subject: BIOLOGIA MOLECULAR Year: 2022 Document type: Article