Your browser doesn't support javascript.
loading
The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities.
Beck, Thomas R; Antohe, Andrei; Cardellini, Francesco; Cucos, Alexandra; Fialova, Eliska; Grossi, Claudia; Hening, Kinga; Jensen, Jens; Kastratovic, Dejan; Krivosík, Matej; Lobner, Patrick; Luca, Aurelian; Maringer, Franz Josef; Michielsen, Nathalie; Otahal, Petr P S; Quindós, Luis; Rábago, Daniel; Sainz, Carlos; Szucs, László; Teodorescu, Constantin; Tolinsson, Cathrin; Tugulan, Cornel Liviu; Turtiainen, Tuukka; Vargas, Arturo; Vosahlik, Josef; Vukoslavovic, Goran; Wiedner, Hannah; Woloszczuk, Katarzyna.
Affiliation
  • Beck TR; Federal Office for Radiation Protection, 10318 Berlin, Germany.
  • Antohe A; Institutul National de Cercetare-Dezvoltare Pentru Fizica si Inginerie Nucleara "Horia Hulubei", 077125 Ilfov County, Romania.
  • Cardellini F; ENEA-INMRI, 00123 Roma, Italy.
  • Cucos A; "CONSTANTIN COSMA" Radon Laboratory, Faculty of Environmental Science and Engineering, Babes-Bolyai University, 400294 Cluj-Napoca, Romania.
  • Fialova E; Státní Ústav Jaderné, Chemické a Biologické Ochrany, 262 31 Milin, Czech Republic.
  • Grossi C; Laboratory of 222Rn Studies, Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, 08028 Barcelona, Spain.
  • Hening K; "CONSTANTIN COSMA" Radon Laboratory, Faculty of Environmental Science and Engineering, Babes-Bolyai University, 400294 Cluj-Napoca, Romania.
  • Jensen J; SwedishRadiation Safety Authority, 171 16 Stockholm, Sweden.
  • Kastratovic D; Bureau of Metrology, Podgorica 81000, Montenegro.
  • Krivosík M; Slovak Institute of Metrology, Department of Ionizing Radiation, 842 55 Bratislava, Slovakia.
  • Lobner P; Physikalisch-Technischer Prüfdienst, Bundesamt für Eich- und Vermessungswesen, 1160 Vienna, Austria.
  • Luca A; Institutul National de Cercetare-Dezvoltare Pentru Fizica si Inginerie Nucleara "Horia Hulubei", 077125 Ilfov County, Romania.
  • Maringer FJ; Physikalisch-Technischer Prüfdienst, Bundesamt für Eich- und Vermessungswesen, 1160 Vienna, Austria.
  • Michielsen N; Institut de Radioprotection et de Sûreté Nucléaire, 92262 Paris, France.
  • Otahal PPS; Státní Ústav Jaderné, Chemické a Biologické Ochrany, 262 31 Milin, Czech Republic.
  • Quindós L; Radon Group, Laboratory of Environmental Radioactivity of the University of Cantabria, 39011 Santander, Spain.
  • Rábago D; Radon Group, Laboratory of Environmental Radioactivity of the University of Cantabria, 39011 Santander, Spain.
  • Sainz C; Radon Group, Laboratory of Environmental Radioactivity of the University of Cantabria, 39011 Santander, Spain.
  • Szucs L; Budapest Fováros Kormányhivatala, 1024 Budapest, Hungary.
  • Teodorescu C; Institutul National de Cercetare-Dezvoltare Pentru Fizica si Inginerie Nucleara "Horia Hulubei", 077125 Ilfov County, Romania.
  • Tolinsson C; SwedishRadiation Safety Authority, 171 16 Stockholm, Sweden.
  • Tugulan CL; Institutul National de Cercetare-Dezvoltare Pentru Fizica si Inginerie Nucleara "Horia Hulubei", 077125 Ilfov County, Romania.
  • Turtiainen T; Radiation and Nuclear Safety Authority, 00880 Helsinki, Finland.
  • Vargas A; Laboratory of 222Rn Studies, Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, 08028 Barcelona, Spain.
  • Vosahlik J; Státní Ústav Jaderné, Chemické a Biologické Ochrany, 262 31 Milin, Czech Republic.
  • Vukoslavovic G; Bureau of Metrology, Podgorica 81000, Montenegro.
  • Wiedner H; Physikalisch-Technischer Prüfdienst, Bundesamt für Eich- und Vermessungswesen, 1160 Vienna, Austria.
  • Woloszczuk K; Central Laboratory for Radiological Protection, 03-194 Warsaw, Poland.
Article in En | MEDLINE | ID: mdl-34831904
An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiation Protection / Radiation Monitoring / Radon / Air Pollutants, Radioactive Type of study: Prognostic_studies Limits: Humans Language: En Journal: Int J Environ Res Public Health Year: 2021 Document type: Article Affiliation country: Alemania Country of publication: Suiza

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiation Protection / Radiation Monitoring / Radon / Air Pollutants, Radioactive Type of study: Prognostic_studies Limits: Humans Language: En Journal: Int J Environ Res Public Health Year: 2021 Document type: Article Affiliation country: Alemania Country of publication: Suiza