Your browser doesn't support javascript.
loading
Safely Inserting Neonatal Chest Drains.
Goelz, Rangmar; Krumrey, Sabrina; Dietz, Klaus; Esser, Michael; Poets, Christian F.
Affiliation
  • Goelz R; Department of Neonatology, University Children's Hospital Tuebingen, Tübingen, Germany.
  • Krumrey S; Center for Anesthesia and Intensive Care Medicine, Klinikverbund Suedwest, Boeblingen, Germany.
  • Dietz K; Emeritus Professor, Department of Medical Biometry, University of Tuebingen, Tübingen, Germany.
  • Esser M; Department of Pediatric Radiology, University Hospital Tuebingen, Tübingen, Germany.
  • Poets CF; Department of Neonatology, University Children's Hospital Tuebingen, Tübingen, Germany.
Neonatology ; 119(1): 33-40, 2022.
Article in En | MEDLINE | ID: mdl-34844248
BACKGROUND: Inserting a chest drain for a left-sided neonatal pneumothorax carries a risk of penetrating the pericardium. We identified reference ranges for the chest wall thickness (CWT) and distance between the pericardium and parietal pleura to improve safety of chest tube insertion. METHOD: We prospectively measured the CWT using ultrasound in 20 neonates (body weight [BW] 640-2,700 g, age <10 days) at the usual site of puncture in the 4th and 5th intercostal space (ICS). Furthermore, we measured the minimal distance between the parietal pleura and the cardiac silhouette in 131 neonatal chest X-rays (birth weight, 420-4,930 g [divided into 11 weight groups]; age <10 days). Both data sets were transformed into weight-dependent percentiles (Ps). We considered the difference between the sum of P 2.5 for the CWT plus P 2.5 for pleura-heart distance minus P 97.5 for the CWT as a safe corridor for placing the tip of the needle. RESULTS: At both ICSs, curves for the above metrics did not cross, indicating a narrow but safe corridor for each BW with at least 97.5% probability. This safety corridor was 4.6-5.2 mm wide for the 4th and 2.8-3.4 mm for the 5th ICS. CONCLUSION: These data offer a reference for left-sided chest drain insertion for BW <2,700 g, which may help to improve safety of the procedure.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pneumothorax / Thoracic Wall Type of study: Etiology_studies Limits: Humans / Newborn Language: En Journal: Neonatology Journal subject: PERINATOLOGIA Year: 2022 Document type: Article Affiliation country: Alemania Country of publication: Suiza

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pneumothorax / Thoracic Wall Type of study: Etiology_studies Limits: Humans / Newborn Language: En Journal: Neonatology Journal subject: PERINATOLOGIA Year: 2022 Document type: Article Affiliation country: Alemania Country of publication: Suiza