Your browser doesn't support javascript.
loading
Consolidating the potency of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) in viral diagnosis: Extrapolating its applicability for COVID diagnosis?
Sivanesan, Iyyakkannu; Gopal, Judy; Surya Vinay, Rohit; Luke, Elizabeth Hanna; Oh, Jae-Wook; Muthu, Manikandan.
Affiliation
  • Sivanesan I; Department of Bioresources and Food Science, Konkuk University, 1, Hwayang-dong, Gwangjin-gu, Seoul, 05029, South Korea.
  • Gopal J; Department of Bioresources and Food Science, Konkuk University, 1, Hwayang-dong, Gwangjin-gu, Seoul, 05029, South Korea.
  • Surya Vinay R; Tagore Medical College and Hospital, Rathinamangalam, Melakottaiyur, Chennai, Tamil Nadu, 600127, India.
  • Luke EH; ICMR- National Institute for Research in Tuberculosis, Chennai, Tamil Nadu, 600031, India.
  • Oh JW; Department of Stem Cell and Regenerative Biotechnology, Konkuk University, Seoul, 143-701, South Korea.
  • Muthu M; Department of Bioresources and Food Science, Konkuk University, 1, Hwayang-dong, Gwangjin-gu, Seoul, 05029, South Korea.
Trends Analyt Chem ; 150: 116569, 2022 May.
Article in En | MEDLINE | ID: mdl-35221399
ABSTRACT
MALDI-TOF-MS has essentially delivered more than expected with respect to clinical pathogens. Viruses are the most versatile entities of clinical pathogens that have challenged well-established microbiological methodologies. This review evaluates the existing scenario with respect to MALDI TOF-MS analytical technique in the successful analysis of viral pathogens. The milestones achieved with respect to detection and identification of COVID-19 has been presented. The fact that only a handful of scattered applications for COVID-19 exist has been pointed out in the review. Further, the lapses in the utilization of the available state-of-the art MALDI-TOF-MS variants/benchmark sophistications for COVID-19 analysis, are highlighted. When the world is seeking for rapid solutions for early, sensitive, rapid COVID-19 diagnosis, maybe MALDI-TOF-MS, may be the actual 'gold standard'. Reverting to the title, this review emphasizes that there is a need for extrapolating MALDI-TOF-MS for COVID-19 analysis and this calls for urgent scientific attention.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: Trends Analyt Chem Year: 2022 Document type: Article Affiliation country: Corea del Sur