Your browser doesn't support javascript.
loading
Feasibility of precise commissural and coronary alignment with balloon-expandable TAVI.
Santos-Martínez, Sandra; Redondo, Alfredo; González-Bartol, Esther; Barrero, Alejandro; Sánchez-Luna, Juan Pablo; Revilla-Orodea, Ana; Baladrón, Carlos; Serrador, Ana; San Román, J Alberto; Amat-Santos, Ignacio J.
Affiliation
  • Santos-Martínez S; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • Redondo A; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • González-Bartol E; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • Barrero A; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • Sánchez-Luna JP; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • Revilla-Orodea A; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovaculares (CIBERCV), Spain.
  • Baladrón C; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovaculares (CIBERCV), Spain.
  • Serrador A; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain.
  • San Román JA; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovaculares (CIBERCV), Spain.
  • Amat-Santos IJ; Departamento de Cardiología, Hospital Clínico Universitario de Valladolid, Valladolid, Spain; Centro de Investigación Biomédica en Red Enfermedades Cardiovaculares (CIBERCV), Spain. Electronic address: ijamat@gmail.com.
Rev Esp Cardiol (Engl Ed) ; 76(1): 19-24, 2023 Jan.
Article in En, Es | MEDLINE | ID: mdl-35570121
INTRODUCTION AND OBJECTIVES: We aimed to describe the feasibility and preliminary outcomes of commissural alignment (CA) for the balloon-expandable transcatheter heart valve. METHODS: The relationship among native commissures and transcatheter aortic valve implantation neocommissures was analyzed in 10 consecutive patients with tricuspid severe aortic stenosis undergoing transcatheter aortic valve implantation after guided implantation based on computed tomography analysis with a self-developed software. CA was predicted by in silico bio-modelling in the 10 patients and the calculated rotation was applied during crimping. Degrees of CA and coronary overlap (CO) were measured through 1-month follow up computed tomography. Transvalvular residual gradients and the rate of paravalvular leak were also analyzed. RESULTS: Mean commissural misalignment was 16.7±8°. Four patients showed mild misalignment but none of them showed a moderate or severe degree of misalignment. The in silico model accurately predicted the final in vivo position with a correlation coefficient of 0.983 (95%CI, 0.966-0.992), P <.001. Severe CO with right coronary ostium occurred in 3 patients likely due to ostial eccentricity, and CO was not present with the left coronary artery in any of the patients. Mean transaortic gradient was 6.1±3.3mmHg and there were no moderate-severe paravalvular leaks. CONCLUSIONS: Patient-specific rotation during valve crimping based on preprocedural computed tomography is feasible with balloon-expandable devices and is associated with the absence of moderate or severe commissural misalignment and left main CO.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Type of study: Prognostic_studies Limits: Humans Language: En / Es Journal: Rev Esp Cardiol (Engl Ed) Year: 2023 Document type: Article Affiliation country: España Country of publication: España

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Heart Valve Prosthesis / Transcatheter Aortic Valve Replacement Type of study: Prognostic_studies Limits: Humans Language: En / Es Journal: Rev Esp Cardiol (Engl Ed) Year: 2023 Document type: Article Affiliation country: España Country of publication: España