Supraglottic Airways Compared With Face Masks for Neonatal Resuscitation: A Systematic Review.
Yamada, Nicole K; McKinlay, Christopher Jd; Quek, Bin Huey; Schmölzer, Georg M; Wyckoff, Myra H; Liley, Helen G; Rabi, Yacov; Weiner, Gary M.
Affiliation
  • Yamada NK; Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University School of Medicine, Palo Alto, California.
  • McKinlay CJ; Kidz First Neonatal Care, Counties Manukau Health, Auckland, New Zealand.
  • Quek BH; Liggins Institute, University of Auckland, Auckland, New Zealand.
  • Schmölzer GM; Department of Neonatology, KK Women's and Children's Hospital, Singapore, Singapore.
  • Wyckoff MH; Centre for the Studies of Asphyxia and Resuscitation, Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
  • Liley HG; Division of Neonatal-Perinatal Medicine, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, Texas.
  • Rabi Y; Mater Research Institute and Mater Clinical School, Faculty of Medicine, The University of Queensland, Brisbane, Australia.
  • Weiner GM; Department of Pediatrics, University of Calgary, Calgary, Alberta, Canada.
Pediatrics ; 150(3)2022 09 01.
Article in En | MEDLINE | ID: mdl-35948789
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Positive pressure ventilation (PPV) is the most important component of neonatal resuscitation, but face mask ventilation can be difficult. Compare supraglottic airway devices (SA) with face masks for term and late preterm infants receiving PPV immediately after birth.

METHODS:

Data sources include Medline, Embase, Cochrane Databases, Database of Abstracts of Reviews of Effects, and Cumulative Index to Nursing and Allied Health Literature. Study selections include randomized, quasi-randomized, interrupted time series, controlled before-after, and cohort studies with English abstracts. Two authors independently extracted data and assessed risk of bias and certainty of evidence. The primary outcome was failure to improve with positive pressure ventilation. When appropriate, data were pooled using fixed effect models.

RESULTS:

Meta-analysis of 6 randomized controlled trials (1823 newborn infants) showed that use of an SA decreased the probability of failure to improve with PPV (relative risk 0.24; 95% confidence interval 0.17 to 0.36; P <.001, moderate certainty) and endotracheal intubation (4 randomized controlled trials, 1689 newborn infants) in the delivery room (relative risk 0.34, 95% confidence interval 0.20 to 0.56; P <.001, low certainty). The duration of PPV and time until heart rate >100 beats per minute was shorter with the SA. There was no difference in the use of chest compressions or epinephrine during resuscitation. Certainty of evidence was low or very low for most outcomes.

CONCLUSIONS:

Among late preterm and term infants who require resuscitation after birth, ventilation may be more effective if delivered by SA rather than face mask and may reduce the need for endotracheal intubation.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Resuscitation / Masks Type of study: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies / Systematic_reviews Limits: Humans / Newborn Language: En Journal: Pediatrics Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Resuscitation / Masks Type of study: Clinical_trials / Etiology_studies / Observational_studies / Risk_factors_studies / Systematic_reviews Limits: Humans / Newborn Language: En Journal: Pediatrics Year: 2022 Document type: Article