Efficacy of ICD/CRT-D Remote Monitoring in Patients With HFrEF: a Bayesian Meta-analysis of Randomized Controlled Trials.
Curr Heart Fail Rep
; 19(6): 435-444, 2022 12.
Article
in En
| MEDLINE
| ID: mdl-36205832
ABSTRACT
PURPOSE OF REVIEW To evaluate remote monitoring using implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) devices as an adjunctive tool to the traditional care of patients with heart failure (HF). RECENT FINDINGS:
We included 11 trials encompassing 5965 patients. Absolute risk difference (ARD) with 95% credible interval (CrI) was estimated. Pooled (posterior) risk difference was computed using Bayesian hierarchical methods. The ARD for mortality was centered at - 0.01 (95% CrI - 0.03; 0.01, Tau 0.02), with an 82% probability of ARD of ICD/CRT-D remote monitoring with respect to control being less than 0. The ARD for cardiovascular mortality was centered at - 0.03 (95% CrI - 0.11; 0.05, Tau 0.10), with an 84% probability of ARD of ICD/CRT-D remote monitoring with respect to control being less than 0. ICD/CRT-D remote monitoring in patients with HF is associated with a higher probability of reduced all-cause and cardiovascular mortality compared with standard care alone.Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Defibrillators, Implantable
/
Cardiac Resynchronization Therapy
/
Heart Failure
Type of study:
Clinical_trials
/
Prognostic_studies
/
Systematic_reviews
Limits:
Humans
Language:
En
Journal:
Curr Heart Fail Rep
Journal subject:
CARDIOLOGIA
Year:
2022
Document type:
Article
Affiliation country: