Your browser doesn't support javascript.
loading
Direct, Rapid Detection of Pathogens from Urine Samples.
David, Sorin; Munteanu, Raluca-Elena; Tițoiu, Ana-Maria; Petcu, Ionela-Cristina; Cernat, Ioana-Cristina; Leancu, Corina; Gheorghiu, Mihaela; Gheorghiu, Eugen.
Affiliation
  • David S; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
  • Munteanu RE; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
  • Tițoiu AM; Faculty of Biology, University of Bucharest, Splaiul Independenței 91-95, 050095 Bucharest, Romania.
  • Petcu IC; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
  • Cernat IC; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
  • Leancu C; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
  • Gheorghiu M; Laboratoarele SynLab, Bld. Tudor Vladimirescu nr.29, 050881 Bucharest, Romania.
  • Gheorghiu E; International Centre of Biodynamics, Intrarea Portocalelor 1B, 060101 Bucharest, Romania.
Materials (Basel) ; 15(21)2022 Oct 31.
Article in En | MEDLINE | ID: mdl-36363232
ABSTRACT
The problem of rapidly detecting pathogens directly from clinical samples poses significant analytical challenges. Addressing this issue in relation to urinary tract infections, we propose an effective protocol and related immunomagnetic test kits enabling versatile screening for the presence of pathogenic bacteria in unprocessed urine samples. To achieve this, the components of a typical immunomagnetic separation protocol were optimized towards the sensitive assessment of the aggregates formed out of immunomagnetically tagged target pathogens collected from clinical samples. Specifically, a dedicated immunomagnetic material was developed via the functionalization of standardized, micron-sized magnetic beads with generic antibodies against gram-specific bacterial constituents with mannan binding lectin. As such, we demonstrate efficient procedures for achieving the enhanced, specific, and pathogen-mediated cluster formation of these tailored affinity-coated magnetic beads in complex samples. We further show how cluster analysis, in conjunction with the use of nonspecific, inexpensive fluorescent dye, allows for a straightforward optical assessment of the bacterial load directly from urine samples. The optimized sensing protocol and related kits provide, in less than 60 min, qualitative (positive/negative) information on the bacterial load with 85% specificity and 96% sensitivity, which is appropriate to empower clinical microscopy with a new analytic dimension. The procedure is prone to automation, can be conveniently used in clinical microbiology laboratories and, since it preserves the viability of the captured bacteria, can be interfaced with downstream analyses and antimicrobial susceptibility testing. Moreover, the study emphasizes a suite of practical validation assays that are useful for bringing the tool-box of immunomagnetic materials outside the academic laboratory and into real-life applications.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Guideline / Qualitative_research Language: En Journal: Materials (Basel) Year: 2022 Document type: Article Affiliation country: Rumanía

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Guideline / Qualitative_research Language: En Journal: Materials (Basel) Year: 2022 Document type: Article Affiliation country: Rumanía