Your browser doesn't support javascript.
loading
Variations in the morphology of apical constriction affecting electronic readings: An in vitro investigation using 3D-printed tooth models.
Nam, Juhee; Piasecki, Lucila; Kwak, Doun; Hong, Jung Hwa; Jung, Il-Young; Park, Sung-Ho; Cho, Sin-Yeon.
Affiliation
  • Nam J; Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea.
  • Piasecki L; Department of Periodontics and Endodontics, School of Dental Medicine, University at Buffalo, Buffalo, New York, USA.
  • Kwak D; Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea.
  • Hong JH; Department of Policy Research Affairs, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea.
  • Jung IY; Microscope Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, South Korea.
  • Park SH; Microscope Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, South Korea.
  • Cho SY; Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Kyeonggi-do, South Korea.
Aust Endod J ; 49 Suppl 1: 245-252, 2023 Sep.
Article in En | MEDLINE | ID: mdl-36448774
ABSTRACT
We investigated the interference of apical constriction position and diameter on the accuracy of electronic apex locators using 3D-printed tooth models. Single-rooted tooth models with the same length, canal taper and major foramen, but variation in apical constriction position or size, were designed and 3D-printed. A mounting model was custom-made for precise measurement of both marks (0.5 and APEX/0.0) of two electronic apex locators. The electronic measurements of both devices were correlated significantly to the major foramen rather than apical constriction. The mean measurements of the group with 0.45 mm in apical constriction width were significantly shorter than those of the other groups for both marks of the two devices (p < 0.05). The variations in apical constriction position and width negatively affected the precision of the 0.5 mark of the tested devices. The 0.0 or APEX mark was consistently located the major foramen.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tooth Apex / Dental Pulp Cavity Language: En Journal: Aust Endod J Journal subject: ODONTOLOGIA Year: 2023 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tooth Apex / Dental Pulp Cavity Language: En Journal: Aust Endod J Journal subject: ODONTOLOGIA Year: 2023 Document type: Article