Your browser doesn't support javascript.
loading
Tooth Complications after Orthodontic Miniscrews Insertion.
Inchingolo, Angelo Michele; Malcangi, Giuseppina; Costa, Stefania; Fatone, Maria Celeste; Avantario, Pasquale; Campanelli, Merigrazia; Piras, Fabio; Patano, Assunta; Ferrara, Irene; Di Pede, Chiara; Netti, Anna; de Ruvo, Elisabetta; Palmieri, Giulia; Settanni, Vito; Carpentiere, Vincenzo; Tartaglia, Gianluca Martino; Bordea, Ioana Roxana; Lorusso, Felice; Sauro, Salvatore; Di Venere, Daniela; Inchingolo, Francesco; Inchingolo, Alessio Danilo; Dipalma, Gianna.
Affiliation
  • Inchingolo AM; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Malcangi G; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Costa S; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Fatone MC; PTA Trani-ASL BT, Viale Padre pio, 76125 Trani, Italy.
  • Avantario P; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Campanelli M; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Piras F; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Patano A; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Ferrara I; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Di Pede C; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Netti A; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • de Ruvo E; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Palmieri G; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Settanni V; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Carpentiere V; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Tartaglia GM; UOC Maxillo-Facial Surgery and Dentistry, Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, University of Milan, 20100 Milan, Italy.
  • Bordea IR; Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania.
  • Lorusso F; Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy.
  • Sauro S; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Di Venere D; Dental Biomaterials and Minimally Invasive Dentistry, Department of Dentistry, University CEU Cardenal Herrera, CEU Universities, C/Santiago Ramón y Cajal, s/n., Alfara del Patriarca, 46115 Valencia, Spain.
  • Inchingolo F; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Inchingolo AD; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
  • Dipalma G; Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124 Bari, Italy.
Article in En | MEDLINE | ID: mdl-36674316
ABSTRACT
Orthodontic miniscrews (OM) are widely used in modern orthodontic clinical practice to improve skeletal anchorage and have a high safety profile. A complication at the time of OM insertion is tooth root perforation or periodontal ligament trauma. Rarely, OM injury can cause permanent damage, such as ankylosis, osteosclerosis, and loss of tooth vitality. The aim of this work was to analyze potential risks and dental complications associated with the use of OMs. A search of the PubMed, Cochrane, Web of Science, and Scopus databases was conducted without a time limit using the keywords "orthodontic mini-screw" and "dental damage", resulting in 99 studies. After screening and eligibility, including articles obtained through a citation search, 13 articles were selected. Four studies revealed accidental injuries caused by OM. Most of the damage was localized at the root level and resolved spontaneously with restorative cement formation after prompt removal of the OM, while the pain disappeared. In some cases, irreversible nerve damage, extensive lesions to the dentin-pulp complex, and refractory periapical periodontitis occurred, requiring endodontic and/or surgical treatment. The choice of insertion site was the most important element to be evaluated during the application of OMs.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tooth Root / Bone Screws Language: En Journal: Int J Environ Res Public Health Year: 2023 Document type: Article Affiliation country: Italia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tooth Root / Bone Screws Language: En Journal: Int J Environ Res Public Health Year: 2023 Document type: Article Affiliation country: Italia
...