Your browser doesn't support javascript.
loading
Use of a high-speed drill in robotics coupled with navigation for pediatric spine surgery.
Mota, Frank; Welch, Nicole; Montgomery, Blake K; Birch, Craig; Hedequist, Daniel.
Affiliation
  • Mota F; Department of Orthopaedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
  • Welch N; Department of Orthopaedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
  • Montgomery BK; Department of Orthopaedic Surgery, Boston Children's Hospital, Harvard Medical School, 300 Longwood Avenue, Boston, MA, 02115, USA.
  • Birch C; Department of Orthopaedic Surgery, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
  • Hedequist D; Harvard Medical School, Boston, MA, USA.
J Robot Surg ; 17(4): 1511-1516, 2023 Aug.
Article in En | MEDLINE | ID: mdl-36862349
ABSTRACT
With the increasing number of surgeries for pediatric spinal deformities, the aim has been to reduce the associated complications, such as those caused by screw malposition. This case series is an intra-operative experience with a new navigated high-speed revolution drill (Mazor Midas, Medtronic, Minneapolis, MN) for pediatric spinal deformity to assess accuracy and workflow. 88 patients, ranging from 2 to 29 years of age, were included who underwent posterior spinal fusion with the navigated high-speed drill. Diagnoses, Cobb angles, imaging, surgical time, complications, and total number of screws placed are described. Screw positioning was evaluated using fluoroscopy, plain radiography, and CT. Mean age was 15.4 years old. Diagnoses included 47 adolescent idiopathic scoliosis, 15 neuromuscular scoliosis, 8 spondylolisthesis, 4 congenital scoliosis, and 14 other. The mean Cobb angulation for scoliosis patients was 64° and the mean number of levels fused was 10. 81 patients had registration via intraoperative 3-D imaging and 7 had pre-operative CT scan to fluoroscopy registration. There were a total of 1559 screws with 925 placed robotically. 927 drill paths were drilled with the Mazor Midas. 926 out of 927 drill paths were accurate. The mean surgical time was 304 min with the mean robotic time being 46 min. This is the first intra-operative report to our knowledge documenting the experience with the Mazor Midas drill in pediatric spinal deformity showing decreased skiving potential, decreased torque when drilling, and lastly increased accuracy. Level of evidence level III.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scoliosis / Surgery, Computer-Assisted / Robotic Surgical Procedures / Pedicle Screws Type of study: Observational_studies / Risk_factors_studies Limits: Adolescent / Child / Humans Language: En Journal: J Robot Surg Year: 2023 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Scoliosis / Surgery, Computer-Assisted / Robotic Surgical Procedures / Pedicle Screws Type of study: Observational_studies / Risk_factors_studies Limits: Adolescent / Child / Humans Language: En Journal: J Robot Surg Year: 2023 Document type: Article Affiliation country: Estados Unidos