Your browser doesn't support javascript.
loading
A strategy to reduce fraction number in peripheral lung stereotactic ablative body radiotherapy.
O'Keeffe, Serena; Higgins, Martin J; Fleming, Cathy; Armstrong, John; Thirion, Pierre; McClean, Brendan; Vintró, Luis León.
Affiliation
  • O'Keeffe S; Department of Physics, St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland.
  • Higgins MJ; UCD School of Physics, University College Dublin, Ireland.
  • Fleming C; St Luke's Institute of Cancer Research, Dublin, Ireland.
  • Armstrong J; St Luke's Institute of Cancer Research, Dublin, Ireland.
  • Thirion P; Department of Radiation Oncology, St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland.
  • McClean B; Department of Physics, St. Luke's Radiation Oncology Network, St. Luke's Hospital, Dublin, Ireland.
  • Vintró LL; St Luke's Institute of Cancer Research, Dublin, Ireland.
Phys Imaging Radiat Oncol ; 26: 100429, 2023 Apr.
Article in En | MEDLINE | ID: mdl-37007915
ABSTRACT
Background and

purpose:

Hypo-fractionated lung Stereotactic Ablative Body Radiotherapy (SABR) has often been avoided when tumours are close to the chest wall. Our strategic objective was the reduction of fraction number, while maintaining target biological effective dose coverage without increasing chest wall toxicity (CWT) predictors. Materials and

methods:

Twenty previously treated lung SABR patients were stratified into four cohorts according to distance from PTV to the chest wall, <1 cm, <0.5 cm, overlapping up to 0.5 cm and 1.0 cm. For each patient, four plans were created; a chest wall optimised plan for 54 Gy in 3 fractions, the clinical plan re-prescribed for 55 Gy in 5, 48 Gy in 3 and 45 Gy in 3 fractions.

Results:

For a PTV distance of 0.5-0.0 cm, a reduction of the median (range) Dmax from 55.7 (57.5-54.1) Gy to 40.0 (37.1-42.0 Gy) Gy was observed for the chest wall optimised plans. The median V30Gy decreased from 18.9 (9.7-25.6) cm3 to 3.1 (1.8-4.5) cm3. For a PTV overlap of up to 0.5 cm, the Dmax reduced from 66.5 (64.1-70) Gy to 53.2 (50.6-55.1) Gy. The V30Gy decreased from 21.5 (16.5-29.5) cm3 to 14.9 (11.3-20.2) cm3. For the cohort with up to 1.0 cm overlap, there was a reduction in Dmax values of 9.9 Gy. The V30Gy for clinical plans, at 66.8 (18.7-188.8) cm3, decreased to 55.3 (15.5-149) cm3.

Conclusion:

When PTVs are within 0.5 cm of chest wall, lung SABR dose heterogeneity can be used to reduce fraction number without increasing CWT predictors.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Phys Imaging Radiat Oncol Year: 2023 Document type: Article Affiliation country: Irlanda

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Phys Imaging Radiat Oncol Year: 2023 Document type: Article Affiliation country: Irlanda