Your browser doesn't support javascript.
loading
Combined genetic screening and traditional newborn screening to improve the screening efficiency of congenital hypothyroidism.
Ye, Liang; Yin, Yifan; Chen, Min; Gong, Nian; Peng, Yong; Liu, Hao; Miao, Jingkun.
Affiliation
  • Ye L; Department of Pediatrics, Women and Children' Hospital of Chongqing Medical University, Chongqing, China.
  • Yin Y; Department of Pediatrics, Chongqing Health Center for Women and Children, Chongqing, China.
  • Chen M; Department of Pediatrics, Women and Children' Hospital of Chongqing Medical University, Chongqing, China.
  • Gong N; Department of Pediatrics, Chongqing Health Center for Women and Children, Chongqing, China.
  • Peng Y; Department of Pediatrics, Women and Children' Hospital of Chongqing Medical University, Chongqing, China.
  • Liu H; Department of Pediatrics, Chongqing Health Center for Women and Children, Chongqing, China.
  • Miao J; Department of Pediatrics, Women and Children' Hospital of Chongqing Medical University, Chongqing, China.
Front Pediatr ; 11: 1185802, 2023.
Article in En | MEDLINE | ID: mdl-37252044
ABSTRACT

Background:

Congenital hypothyroidism (CH) is an neonatal endocrine disorder. Traditional newborn screening is the mainstream method of CH screening, so as to ensure the early detection and treatment of CH. This method is limited as it has high rates of false positives and negatives. Genetic screening can be used to address the shortcomings of traditional newborn Screening (NBS); however, the comprehensive clinical value of genetic screening is yet to be systematically studied.

Methods:

A total of 3,158 newborns who accepted the newborn screening and genetic screening were recruited for this study. Biochemical screening and genetic screening were performed at the same time. The level of TSH with the DBS was detected by time-resolved immunofluorescence assay. High-throughput sequencing technology based on targeted gene capture was used for genetic screening. The suspected neonatal was recalled and tested serum TSH, and FT4. Finally, the effectiveness of traditional NBS and combined screening was compared.

Results:

In this study, 16 cases were diagnosed by traditional NBS. 10 cases of DUOX2 mutation were found in newborn CH-related genetic screening, including 5 homozygous and 5 compound heterozygous variations. We found that the c.1588A > T mutations in DUOX2 constituting the predominant site in the present cohort.Compared with NBS and genetic screening, the sensitivity of combined screening increased by 11.1% and 55.6%, respectively. Compared with NBS and genetic screening, the negative predictive value of combined screening increased by 0.1% and 0.4%, respectively.

Conclusions:

Combined traditional NBS and genetic screening reduces the false negative rate of CH screening and improves the early and accurate identification of neonates with CH. Our research explains the mutation spectrum of CH in this region, and provisionally demonstrates the necessity, feasibility and significance of genetic screening in newborns and provides a solid basis for future clinical developments.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Screening_studies Language: En Journal: Front Pediatr Year: 2023 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Screening_studies Language: En Journal: Front Pediatr Year: 2023 Document type: Article Affiliation country: China