Your browser doesn't support javascript.
loading
Development and evaluation of automated synovial fluid total cell count on an Iris iQ® 200 for identifying patients at risk of septic arthritis.
Ruffier d'Epenoux, L; Fayoux, E; Bémer, P; Biering, V; Bonte, A; Elaiba, Y; Robert, M; Guillouzouic, A; Tessier, E; Persyn, E; Corvec, S.
Affiliation
  • Ruffier d'Epenoux L; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Fayoux E; Université de Nantes, CHU Nantes, INSERM, INCIT UMR 1302, F-44000, Nantes, France.
  • Bémer P; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Biering V; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Bonte A; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Elaiba Y; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Robert M; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Guillouzouic A; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Tessier E; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Persyn E; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
  • Corvec S; Service de Bactériologie et des Contrôles Microbiologiques, CHU Nantes, Nantes, France.
Eur J Clin Microbiol Infect Dis ; 42(8): 1031-1036, 2023 Aug.
Article in En | MEDLINE | ID: mdl-37256456
ABSTRACT
Septic arthritis is a diagnostic emergency. The white blood cell (WBC) count, in synovial fluid (SF), can guide the diagnosis. From November 2021 to November 2022, we included 350 SF. The WBC count was performed with the Iris iQ® 200 compared with the manual method. Automated and manual counts displayed good correlation. However, a Bland Altman plot demonstrates a higher percentage difference at higher WBC counts. The use of Iris iQ® 200 for SF analysis enables a rapid and accurate assessment for WBC count. Its implementation would advantageously replace the long and tedious optical analysis in daily routine.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Synovial Fluid / Arthritis, Infectious Type of study: Diagnostic_studies / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: Eur J Clin Microbiol Infect Dis Journal subject: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Year: 2023 Document type: Article Affiliation country: Francia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Synovial Fluid / Arthritis, Infectious Type of study: Diagnostic_studies / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limits: Humans Language: En Journal: Eur J Clin Microbiol Infect Dis Journal subject: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Year: 2023 Document type: Article Affiliation country: Francia