Your browser doesn't support javascript.
loading
Evaluation of reproducible cryogel preparation based on automated image analysis using deep learning.
Behrendt, Florian; Cseresnyés, Zoltán; Gerst, Ruman; Gottschaldt, Michael; Figge, Marc Thilo; Schubert, Ulrich S.
Affiliation
  • Behrendt F; Laboratory of Organic Chemistry and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Jena, Germany.
  • Cseresnyés Z; Jena Center for Soft Matter (JCSM), Friedrich Schiller University Jena, Jena, Germany.
  • Gerst R; Applied Systems Biology, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, Jena, Germany.
  • Gottschaldt M; Applied Systems Biology, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, Jena, Germany.
  • Figge MT; Institute of Microbiology, Faculty of Biological Sciences, Friedrich Schiller University Jena, Jena, Germany.
  • Schubert US; Laboratory of Organic Chemistry and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Jena, Germany.
J Biomed Mater Res A ; 111(11): 1734-1749, 2023 11.
Article in En | MEDLINE | ID: mdl-37345381
ABSTRACT
Cryogels represent a class of porous sponge-like materials possessing unique properties including high-fidelity reproduction of tissue structure and maximized permeability. Their architecture is mainly based on an interconnected network of macropores that provides sufficient stability while allowing the movement of substances through the material. In most cryogel applications, the pore size is very important, especially when the material is used as a 3D scaffold for tissue culture, applied as a filter, or utilized as a membrane. In this study, poly(dimethylacrylamide-co-2-hydroxyethyl methacrylate) cryogels have been prepared by two preparation methods to investigate the reproducibility of homogeneous pore structures and pore sizes. Automated image analysis algorithms were developed to rapidly evaluate cryogel pore sizes based on scanning electron microscopy (SEM) images. The quantification approach contained a unique combination of classical and deep learning-based algorithms. To validate the accuracy of the two models, we compared the results obtained from automated SEM image analysis with those from manual pore size determinations and mercury intrusion porosimetry (MIP) measurements. Effect sizes were calculated to compare the results from manual and automated pore size measurements for the cryogel reproducibility series. 81% of the values obtained revealed only trivial differences, which strongly suggests that automated image analysis can reliably substitute the manual evaluation of cryogel pore sizes. The use of an adapted reactor setup yielded cryogels with heterogeneous morphologies in the absence of recognizable pore structures. With the conventional cryogel preparation using plastic syringes, the obtained cryogels represented highly reproducible morphologies and pore sizes in the range between 17 and 22 µm. Calculated effect sizes within the cryogel replicate series revealed only trivial differences between the obtained pore sizes in 83.5% or 99.4% of the data (classical approach and deep learning-based approach, respectively).
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cryogels / Deep Learning Type of study: Prognostic_studies Language: En Journal: J Biomed Mater Res A Journal subject: ENGENHARIA BIOMEDICA Year: 2023 Document type: Article Affiliation country: Alemania