Your browser doesn't support javascript.
loading
A Nonlinear-Model-Based High-Bandwidth Current Sensor Design for Switching Current Measurement of Wide Bandgap Devices.
Du, Xia; Du, Liyang; Chen, Yuxiang; Wei, Yuqi; Stratta, Andrea; Mantooth, Homer Alan.
Affiliation
  • Du X; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
  • Du L; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
  • Chen Y; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
  • Wei Y; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
  • Stratta A; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
  • Mantooth HA; Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
Sensors (Basel) ; 23(10)2023 May 10.
Article in En | MEDLINE | ID: mdl-37430537
ABSTRACT
With the growing adoption of wide bandgap devices in power electronic applications, current sensor design for switching current measurement has become more important. The demands for high accuracy, high bandwidth, low cost, compact size, and galvanic isolation pose significant design challenges. The conventional modeling approach for bandwidth analysis of current transformer sensors assumes that the magnetizing inductance remains constant, which does not always hold true in high-frequency operations. This can result in inaccurate bandwidth estimation and affect the overall performance of the current sensor. To address this limitation, this paper provides a comprehensive analysis of nonlinear modeling and bandwidth, considering the varying magnetizing inductance in a wide frequency range. A precise and straightforward arctangent-based fitting algorithm was proposed to accurately emulate the nonlinear feature, and the fitting results were compared with the magnetic core's datasheet to confirm its accuracy. This approach contributes to more accurate bandwidth prediction in field applications. In addition, the droop phenomenon of the current transformer and saturation effects are analyzed in detail. For high-voltage applications, different insulation methods are compared and an optimized insulation process is proposed. Finally, the design process is experimentally validated. The bandwidth of the proposed current transformer is around 100 MHz and the cost is around $20, making it a low-cost and high-bandwidth solution for switching current measurements in power electronic applications.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Sensors (Basel) Year: 2023 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Sensors (Basel) Year: 2023 Document type: Article Affiliation country: Estados Unidos