Your browser doesn't support javascript.
loading
Pre-TAVI aortic annulus sizing: comparison between manual and semi-automated new generation software measurements in operators with different experience.
Annoni, Andrea Daniele; Mancini, Maria Elisabetta; Carlicchi, Eleonora; Belmonte, Marta; Formenti, Alberto; Mushtaq, Saima; Marchetti, Francesca; Cilia, Francesco; Baggiano, Andrea; Fusini, Laura; Bonomi, Alice; Gennari, Marco; Montorsi, Piero; Pepi, Mauro; Pontone, Gianluca.
Affiliation
  • Annoni AD; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Mancini ME; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Carlicchi E; Centro Cardiologico Monzino, IRCCS, University of Milan, Milan, Italy.
  • Belmonte M; ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Formenti A; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Mushtaq S; Cardiovascular Center Aalst, OLV-Clinic, Aalst, Belgium.
  • Marchetti F; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Cilia F; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Baggiano A; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Fusini L; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Bonomi A; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Gennari M; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Montorsi P; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Pepi M; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Pontone G; Centro Cardiologico Monzino, IRCCS, Milan, Italy.
Br J Radiol ; 96(1149): 20220733, 2023 Sep.
Article in En | MEDLINE | ID: mdl-37449675
ABSTRACT

OBJECTIVES:

Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators.

METHODS:

Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with >5 years and 1 year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared.

RESULTS:

Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81-0.98). Good correlations were found for the distance with coronary ostia(0.75-0.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89 and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus 3.14 min), respectively.

CONCLUSIONS:

Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience. ADVANCES IN KNOWLEDGE The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Transcatheter Aortic Valve Replacement Type of study: Observational_studies Limits: Humans Language: En Journal: Br J Radiol Year: 2023 Document type: Article Affiliation country: Italia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Valve Stenosis / Transcatheter Aortic Valve Replacement Type of study: Observational_studies Limits: Humans Language: En Journal: Br J Radiol Year: 2023 Document type: Article Affiliation country: Italia
...