Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.
da Cunha, Kelly Francisco; Oliveira, Karina Diniz; Costa, Jose Luiz.
Affiliation
  • da Cunha KF; Campinas Poison Control Center, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083­859, Brazil.
  • Oliveira KD; Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083­859, Brazil.
  • Costa JL; Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, 13083­859, Brazil.
Forensic Toxicol ; 42(1): 18-30, 2024 01.
Article in En | MEDLINE | ID: mdl-37505359
ABSTRACT

PURPOSE:

We developed and validated a method for quantitative analysis of ten synthetic cathinones in oral fluid (OF) samples, using microextraction by packed sorbent (MEPS) for sample preparation followed by liquid chromatography‒tandem mass spectrometry (LC‒MS/MS).

METHOD:

OF samples were collected with a Quantisal™ device and 200 µL was extracted using a C18 MEPS cartridge installed on a semi-automated pipette and then analyzed using LC‒M/SMS.

RESULTS:

Linearity was achieved between 0.1 and 25 ng/mL, with a limit of detection (LOD) of 0.05 ng/mL and a limit of quantification (LOQ) of 0.1 ng/mL. Imprecision (% relative standard deviation) and bias (%) were better than 11.6% and 7.5%, respectively. The method had good specificity and selectivity against 9 different blank OF samples (from different donors) and 68 pharmaceutical and drugs of abuse with concentrations varying between 400 and 10,000 ng/mL. No evidence of carryover was observed. The analytes were stable after three freeze/thaw cycles and when kept in the autosampler (10 °C) for up to 24 h. The method was successfully applied to quantify 41 authentic positive samples. Methylone (mean 0.6 ng/mL, median 0.2 ng/mL), N-ethylpentylone (mean 16.7 ng/mL, median 0.35 ng/mL), eutylone (mean 39.1 ng/mL, median 3.6 ng/mL), mephedrone (mean 0.5 ng/mL, median 0.5 ng/mL), and 4-chloroethcathinone (8.1 ng/mL) were quantified in these samples.

CONCLUSION:

MEPS was an efficient technique for Green Analytical Toxicology purposes, which required only 650 µL organic solvent and 200 µL sodium hydroxide, and the BIN cartridge had a lifespan of 100 sample extractions.