Your browser doesn't support javascript.
loading
Evaluation of a high-throughput H295R homogenous time resolved fluorescence assay for androgen and estrogen steroidogenesis screening.
Garnovskaya, Maria; Feshuk, Madison; Stewart, Wendy; Friedman, Katie Paul; Thomas, Russell S; Deisenroth, Chad.
Affiliation
  • Garnovskaya M; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
  • Feshuk M; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
  • Stewart W; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
  • Friedman KP; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
  • Thomas RS; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
  • Deisenroth C; Center for Computational Toxicology and Exposure, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, United States. Electronic address: deisenroth.chad@epa.gov.
Toxicol In Vitro ; 92: 105659, 2023 Oct.
Article in En | MEDLINE | ID: mdl-37557933
ABSTRACT
The H295R test guideline assay evaluates the effect of test substances on synthesis of 17ß-estradiol (E2) and testosterone (T). The objective of this study was to leverage commercial immunoassay technology to develop a more efficient H295R assay to measure E2 and T levels in 384-well format. The resulting Homogenous Time Resolved Fluorescence assay platform (H295R-HTRF) was evaluated against a training set of 36 chemicals derived from the OECD inter-laboratory validation study, EPA guideline 890.1200 aromatase assay, and azole fungicides active in the HT-H295R assay. Quality control performance criteria were met for all conditions except E2 synthesis inhibition where low basal hormone synthesis was observed. Five proficiency chemicals were active for both the E2 and T endpoints, consistent with guideline classifications. Of the nine OECD core reference chemicals, 9/9 were concordant with outcomes for E2 and 7/9 for T. Likewise, 9/13 and 11/13 OECD supplemental chemicals were concordant with anticipated effects for E2 and T, respectively. Of the 10 azole fungicides screened, 7/10 for E2 and 8/10 for T exhibited concordant outcomes for inhibition. Generally, all active chemicals in the training set demonstrated equivalent or greater potency in the H295R-HTRF assay, supporting the sensitivity of the platform. The adaptation of HTRF technology to the H295R model provides an efficient way to evaluate E2 and T modulators in accordance with guideline specifications.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Endocrine Disruptors / Fungicides, Industrial Type of study: Diagnostic_studies / Prognostic_studies / Screening_studies Language: En Journal: Toxicol In Vitro Journal subject: TOXICOLOGIA Year: 2023 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Endocrine Disruptors / Fungicides, Industrial Type of study: Diagnostic_studies / Prognostic_studies / Screening_studies Language: En Journal: Toxicol In Vitro Journal subject: TOXICOLOGIA Year: 2023 Document type: Article Affiliation country: Estados Unidos