A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials.
Spanakis, Elias K; Cook, Curtiss B; Kulasa, Kristen; Aloi, Joseph A; Bally, Lia; Davis, Georgia; Dungan, Kathleen M; Galindo, Rodolfo J; Mendez, Carlos E; Pasquel, Francisco J; Shah, Viral N; Umpierrez, Guillermo E; Aaron, Rachel E; Tian, Tiffany; Yeung, Andrea M; Huang, Jingtong; Klonoff, David C.
Affiliation
  • Spanakis EK; Baltimore VA Medical Center, University of Maryland School of Medicine, Baltimore, MD, USA.
  • Cook CB; Division of Endocrinology, Mayo Clinic Arizona, Scottsdale, AZ, USA.
  • Kulasa K; Division of Endocrinology and Metabolism, Department of Medicine, University of California, San Diego, La Jolla, CA, USA.
  • Aloi JA; Atrium Health Wake Forest Baptist, Winston-Salem, NC, USA.
  • Bally L; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
  • Davis G; Emory University School of Medicine, Atlanta, GA, USA.
  • Dungan KM; Division of Endocrinology, Diabetes & Metabolism, The Ohio State University, Columbus, OH, USA.
  • Galindo RJ; Miller School of Medicine, University of Miami, Miami, FL, USA.
  • Mendez CE; Medical College of Wisconsin, Milwaukee, WI, USA.
  • Pasquel FJ; Emory University School of Medicine, Atlanta, GA, USA.
  • Shah VN; Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, CO, USA.
  • Umpierrez GE; Emory University School of Medicine, Atlanta, GA, USA.
  • Aaron RE; Diabetes Technology Society, Burlingame, CA, USA.
  • Tian T; Diabetes Technology Society, Burlingame, CA, USA.
  • Yeung AM; Diabetes Technology Society, Burlingame, CA, USA.
  • Huang J; Diabetes Technology Society, Burlingame, CA, USA.
  • Klonoff DC; Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA.
J Diabetes Sci Technol ; 17(6): 1527-1552, 2023 11.
Article in En | MEDLINE | ID: mdl-37592726
ABSTRACT
Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.