Your browser doesn't support javascript.
loading
Simultaneous enrichment and sequential elution of cis-diol containing molecules and deoxyribonucleotides with bifunctional boronate and titanium (Ⅳ) ion modified-magnetic nanoparticles prior to quantitation by high performance liquid chromatography.
Sun, Zhian; Sun, Yao; Shen, Jiwei; Wang, Chaozhan; Wei, Yinmao.
Affiliation
  • Sun Z; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710127, China.
  • Sun Y; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710127, China.
  • Shen J; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710127, China.
  • Wang C; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710127, China.
  • Wei Y; Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710127, China. Electronic address: ymwei@nwu.edu.cn.
J Chromatogr A ; 1709: 464386, 2023 Oct 25.
Article in En | MEDLINE | ID: mdl-37722178
ABSTRACT
Some diseases can cause abnormal concentrations of catecholamines (CAs), nucleosides (NSs) and nucleotides (NTs) in patients. Previous studies normally focused on the detection of the three types of substances separately. In this work, a bifunctional boronate and titanium (Ⅳ) ion affinity magnetic adsorbent with high-capacity was prepared. The adsorbent can simultaneously enrich CAs, NSs and NTs in a single extraction process, and the adsorbed analytes can be sequentially eluted by 1.0% trifluoroacetic acid and 20.0 mmol L-1 Na3PO4. An analytical method of the analytes has been established by coupling the adsorbent with RP-HPLC. The method has low detection limits (0.039-0.708 ng mL-1) and good reproducibility (inter- and intra-day of assay RSDs less than 15.0%). Serum sample from healthy volunteer was successfully quantified for two CAs, four NSs and five NTs. Compared with the reported methods, the proposed method is simpler to operate, consume less samples, and has enough accurate and sensitivity to obtain comprehensive information on the concentrations of analytes in a single extraction process.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Chromatogr A Year: 2023 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Chromatogr A Year: 2023 Document type: Article Affiliation country: China
...