Your browser doesn't support javascript.
loading
Biomechanical causes for failure of the Physiomesh/Securestrap system.
Zamkowski, Mateusz; Tomaszewska, Agnieszka; Lubowiecka, Izabela; Smietanski, Maciej.
Affiliation
  • Zamkowski M; Department of General Surgery and Hernia Center, Swissmed Hospital, Wilenska 44, 80-215, Gdansk, Poland. zamek@wp.eu.
  • Tomaszewska A; Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland.
  • Lubowiecka I; Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Gdansk, Poland.
  • Smietanski M; Department of General Surgery and Hernia Center, Swissmed Hospital, Wilenska 44, 80-215, Gdansk, Poland.
Sci Rep ; 13(1): 17504, 2023 10 16.
Article in En | MEDLINE | ID: mdl-37845369
ABSTRACT
This study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh in various directions and the strength of the mesh-tissue-staple junction. Ex-vivo experiments on porcine abdominal wall models were performed to observe the system's behavior under simulated intra-abdominal pressure load. Numerical simulations using finite element analysis were employed to support the experimental findings. The results reveal nonlinearity, anisotropy, and non-homogeneity in the mechanical properties of the Physiomesh, with stress concentration observed in the polydioxanone (PDO) stripe. The mesh-tissue junction exhibited inadequate fixation strength, leading to staple pull-out or breakage. The ex-vivo models demonstrated failure under higher pressure loads. Numerical simulations supported these findings, revealing the reaction forces exceeding the experimentally determined strength of the mesh-tissue-staple junction. The implications of this study extend beyond the specific case of the Physiomesh/Securestrap system, providing insights into the mechanics of implant-tissue systems. By considering biomechanical factors, researchers and clinicians can make informed decisions to develop improved implants that mimic the mechanics of a healthy abdominal wall. This knowledge can contribute to better surgical outcomes and reduce complications in abdominal hernia repair and to avoid similar failures in future.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Abdominal Wall / Hernia, Abdominal Limits: Animals Language: En Journal: Sci Rep Year: 2023 Document type: Article Affiliation country: Polonia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Abdominal Wall / Hernia, Abdominal Limits: Animals Language: En Journal: Sci Rep Year: 2023 Document type: Article Affiliation country: Polonia