Your browser doesn't support javascript.
loading
Intraoperative anteroposterior and oblique fluoroscopic views for detection of mediolateral pedicle screw misplacement in the lumbar spine: a randomized cadaveric study.
Spirig, José Miguel; Fasser, Marie-Rosa; Widmer, Jonas; Wanivenhaus, Florian; Laux, Christoph Johannes; Farshad, Mazda; Passaplan, Caroline.
Affiliation
  • Spirig JM; University Spine Center Zurich, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Fasser MR; Institute for Biomechanics, Balgrist Campus, ETH Zurich, Zurich, Switzerland and Spine Biomechanics, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Widmer J; Institute for Biomechanics, Balgrist Campus, ETH Zurich, Zurich, Switzerland and Spine Biomechanics, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Wanivenhaus F; University Spine Center Zurich, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Laux CJ; University Spine Center Zurich, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Farshad M; University Spine Center Zurich, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Passaplan C; University Spine Center Zurich, Balgrist University Hospital, University of Zurich, Zurich, Switzerland. Electronic address: caroline.passaplan@gmail.com.
Spine J ; 24(4): 730-735, 2024 Apr.
Article in En | MEDLINE | ID: mdl-37871659
ABSTRACT
BACKGROUD CONTEXT Pedicle screws are commonly used for posterior fixation of the lumbar spine. Inaccuracy of screw placement can lead to disastrous complications.

PURPOSE:

As fluoroscopic assisted pedicle screw instrumentation is the most frequently used technique, the aim of this study was to assess the specificity, sensitivity and accuracy of intraoperative fluoroscopy to detect mediolateral screw malpositioning. We also analyzed whether the addition of an oblique view could improve these parameters. STUDY

DESIGN:

On 12 human cadavers, 138 pedicle screws were placed intentionally either with 0 to 2 mm (75 screws), with 2 to 4 mm (six medial and 12 lateral screws) and with >4 mm (22 medial and 23 lateral screws) breach of the pedicle from Th12 to L5.

METHODS:

Three experienced spine surgeons evaluated the screw positioning in fluoroscopic AP views and 4 weeks later in AP views and additional oblique views. The surgeons' interpretation was compared with the effective screw position on postoperative CT scans.

RESULTS:

Pedicle breaches greater than 2 mm were detected in 68% with AP views and in 67% with additional oblique views (p=.742). The specificity of AP views was 0.86 and 0.93 with additional oblique views (p=<.01). The accuracy was 0.78 with AP views and 0.81 with AP + oblique views (p=.114). There was a substantial inter-reader agreement (Fleiss's kappa 0.632).

CONCLUSIONS:

Fluoroscopic screening of pedicle screw misplacement has a limited sensitivity. Adding an oblique view improves specificity but not sensitivity and accuracy in detecting screw malpositions. CLINICAL

SIGNIFICANCE:

When in doubt of a screw malpositioning, other modalities than a fluoroscopic assisted pedicle screw instrumentation such as intraoperative CT imaging or an intraoperative exploration of the screw trajectory must be evaluated.