Investigation of critical factors influencing the underestimation of hearing loss predicted by the ISO 1999 predicting model.
Li, Fei; Xie, Hong-Wei; Su, Shi-Biao; Zou, Hua; ZHou, Li-Fang; Xu, Qiu-Liang; Wei, Fang; Zhang, Mei-Bian.
Affiliation
  • Li F; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • Xie HW; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • Su SB; Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou, China.
  • Zou H; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • ZHou LF; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • Xu QL; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • Wei F; Zhejiang Provincial Center for Disease Control and Prevention, Occupational Health and Radiation Protection Institute, Hangzhou, Zhejiang, China.
  • Zhang MB; Chinese Center for Disease Control and Prevention, National Institute of Occupational Health and Poisoning Control, Beijing, China. zhangmb@niohp.chinacdc.cn.
BMC Public Health ; 23(1): 2239, 2023 11 13.
Article in En | MEDLINE | ID: mdl-37957572
ABSTRACT

OBJECTIVE:

To analyze factors influencing the underestimation of noise-induced permanent threshold shift (NIPTS) among manufacturing workers, providing baseline data for revising noise exposure standard.

DESIGN:

A cross-sectional study was designed with 2702 noise-exposed workers from 35 enterprises from 10 industries. Personal noise exposure level(LAeq,8h) and noise kurtosis level were determined by a noise dosimeter. Questionnaires and hearing loss tests were performed for each subject. The predicted NIPTS was calculated using the ISO 19992013 model for each participant, and the actual measured NIPTS was corrected for age and sex. The factors influencing the underestimation of NIPTS were investigated.

RESULTS:

The predicted NIPTS at each test frequency (0.5, 1, 2, 3, 4, or 6kHz) and mean NIPTS at 2, 3, 4, and 6kHz (NIPTS2346) using the ISO 19992013 model were significantly lower than their corresponding measured NIPTS, respectively (P < 0.001). The ISO model significantly underestimated the NIPTS2346 by 12.36 dB HL. The multiple linear regression analysis showed that noise exposure level, exposure duration, age, and kurtosis could affect the degree of underestimation of NIPTS2346. The generalized additive model (GAM) with (penalized) spline components showed nonlinear relationships between critical factors (age, exposure duration, noise level, and kurtosis) and the underestimated NIPTS2346.The underestimated NIPTS2346 decreased with an increase in exposure duration (especially over ten years). There was no apparent trend in the underestimated NIPTS2346 with age. The underestimated NIPTS2346 decreased with the increased noise level [especially > 90 dB(A)]. The underestimated NIPTS2346 increased with an increase in noise kurtosis after adjusting for the noise exposure level and exposure duration and ultimately exhibiting a linear regression relationship.

CONCLUSIONS:

The ISO 1999 predicting model significantly underestimated the noise-induced hearing loss among manufacturing workers. The degree of underestimation became more significant at the noise exposure condition of fewer than ten years, less than 90 dB(A), and higher kurtosis levels. It is necessary to apply kurtosis to adjust the underestimation of hearing loss and consider the applying condition of noise energy metrics when using the ISO predicting model.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Occupational Exposure / Deafness / Hearing Loss, Noise-Induced / Noise, Occupational / Occupational Diseases Limits: Humans Language: En Journal: BMC Public Health Journal subject: SAUDE PUBLICA Year: 2023 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Occupational Exposure / Deafness / Hearing Loss, Noise-Induced / Noise, Occupational / Occupational Diseases Limits: Humans Language: En Journal: BMC Public Health Journal subject: SAUDE PUBLICA Year: 2023 Document type: Article Affiliation country: China