Your browser doesn't support javascript.
loading
Effects of eccentric loading on performance of concrete columns reinforced with glass fiber-reinforced polymer bars.
Shakouri Mahmoudabadi, Nasim; Bahrami, Alireza; Saghir, Saba; Ahmad, Afaq; Iqbal, Muhammad; Elchalakani, Mohamed; Özkiliç, Yasin Onuralp.
Affiliation
  • Shakouri Mahmoudabadi N; Department of Civil Engineering, The University of Memphis, Memphis, TN, 38152, USA.
  • Bahrami A; Department of Building Engineering, Energy Systems and Sustainability Science, Faculty of Engineering and Sustainable Development, University of Gävle, 801 76, Gävle, Sweden. alireza.bahrami@hig.se.
  • Saghir S; National Highway Authority, Islamabad, Pakistan.
  • Ahmad A; Department of Civil Engineering, The University of Memphis, Memphis, TN, 38152, USA.
  • Iqbal M; Department of Mechanical Engineering, CECOS University of IT and Emerging Sciences, Peshawar, Pakistan.
  • Elchalakani M; Department of Civil Engineering, The University of Western Australia, Perth, Australia.
  • Özkiliç YO; Department of Civil Engineering, Faculty of Engineering, Necmettin Erbakan University, 42100, Konya, Turkey.
Sci Rep ; 14(1): 1890, 2024 Jan 22.
Article in En | MEDLINE | ID: mdl-38253684
ABSTRACT
Glass fiber-reinforced polymer (GFRP) reinforcements are superior to traditional steel bars in concrete structures, particularly in vertical elements like columns, and offer significant advantages over conventional steel bars when subjected to axial and eccentric loadings. However, there is limited experimental and numerical research on the behavior of GFRP-reinforced concrete (RC) columns under eccentric loading having different spacing of stirrups. In this study, six specimens were cast under three different values of eccentricities (25 mm, 50 mm, and 75 mm) with two groups of stirrups spacing (50 mm and 100 mm). The experimental results showed that by increasing the eccentricity value, there was a reduction in the load-carrying capacity of the specimens. The finite element ABAQUS software was used for the numerical investigation of this study. The results from the finite element analysis (FEA) were close to the experimental results and within the acceptable range. The maximum difference between the experimental and FEA results was 3.61% for the axial load and 12.06% for the deformation.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Estados Unidos Country of publication: Reino Unido

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Estados Unidos Country of publication: Reino Unido