Your browser doesn't support javascript.
loading
Determination of Gait Events and Temporal Gait Parameters for Persons with a Knee-Ankle-Foot Orthosis.
Yang, Sumin; Koo, Bummo; Lee, Seunghee; Jang, Dae-Jin; Shin, Hyunjun; Choi, Hyuk-Jae; Kim, Youngho.
Affiliation
  • Yang S; Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
  • Koo B; Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
  • Lee S; Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
  • Jang DJ; Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea.
  • Shin H; Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea.
  • Choi HJ; Korea Orthopedics and Rehabilitation Engineering Center, Incheon 21417, Republic of Korea.
  • Kim Y; Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
Sensors (Basel) ; 24(3)2024 Feb 01.
Article in En | MEDLINE | ID: mdl-38339681
ABSTRACT
Gait event detection is essential for controlling an orthosis and assessing the patient's gait. In this study, patients wearing an electromechanical (EM) knee-ankle-foot orthosis (KAFO) with a single IMU embedded in the thigh were subjected to gait event detection. The algorithm detected four essential gait events (initial contact (IC), toe off (TO), opposite initial contact (OIC), and opposite toe off (OTO)) and determined important temporal gait parameters such as stance/swing time, symmetry, and single/double limb support. These gait events were evaluated through gait experiments using four force plates on healthy adults and a hemiplegic patient who wore a one-way clutch KAFO and a pneumatic cylinder KAFO. Results showed that the smallest error in gait event detection was found at IC, and the largest error rate was observed at opposite toe off (OTO) with an error rate of -2.8 ± 1.5% in the patient group. Errors in OTO detection resulted in the largest error in determining the single limb support of the patient with an error of 5.0 ± 1.5%. The present study would be beneficial for the real-time continuous monitoring of gait events and temporal gait parameters for persons with an EM KAFO.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Foot Orthoses / Ankle Limits: Adult / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Foot Orthoses / Ankle Limits: Adult / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza