Your browser doesn't support javascript.
loading
Experimental study and finite element analysis of heavy-duty escalator truss under full load conditions.
Li, Ning; Cao, Zhongxi; Bao, Wei; Lin, Suixian; Zou, Tao; Yan, Mingming.
Affiliation
  • Li N; School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510000, People's Republic of China.
  • Cao Z; Enterprise Development and Innovation Center, Guangzhou Guangri Elevator Industry Co., Ltd., Guangzhou, 510000, People's Republic of China.
  • Bao W; Escalator Technology Department, Guangzhou Guangri Elevator Industry Co., Ltd., Guangzhou, 510000, People's Republic of China.
  • Lin S; School of Civil Engineering, Guangzhou University, Guangzhou, 510000, People's Republic of China.
  • Zou T; Enterprise Development and Innovation Center, Guangzhou Guangri Elevator Industry Co., Ltd., Guangzhou, 510000, People's Republic of China. lin.x@163.com.
  • Yan M; School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510000, People's Republic of China.
Sci Rep ; 14(1): 4825, 2024 Feb 28.
Article in En | MEDLINE | ID: mdl-38413646
ABSTRACT
The performance of the heavy-duty escalator truss greatly affects the stability and service life of the whole escalator system, and the manufacturing cost of truss structure accounts for more than 1/5. Thus, how to design the truss structure reasonably is a pivotal issue drawing the attention of numerous engineers and researchers. In this work, the experimental research of heavy-duty escalators under full load conditions were performed in terms of the end restraints, the docking port clearances, and the deflection. Based on the experimental results, the three-dimensional simulation model of truss structure was created, and the influences of various factors such as the internal chamfer of truss member, the lower deviation of truss member, the dead weight of escalator, and the pretension force of each bolt at the docking port were analyzed and quantified. Finally, the finite element model which can almost completely characterize the actual structure was obtained with slight difference. The conclusions drawn in this work provide the basis for the efficient design, correct simulation, low cost production and rapid installation of the heavy-duty escalator truss.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep / Sci. rep. (Nat. Publ. Group) / Scientific reports (Nature Publishing Group) Year: 2024 Document type: Article Country of publication: Reino Unido

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep / Sci. rep. (Nat. Publ. Group) / Scientific reports (Nature Publishing Group) Year: 2024 Document type: Article Country of publication: Reino Unido