Your browser doesn't support javascript.
loading
Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography.
Bawazeer, Naif; Gagnon, Carolanne; Maheu, Maxime; Saliba, Issam.
Affiliation
  • Bawazeer N; Division of Otolaryngology-Head & Neck Surgery, University of Montreal, Montreal, Québec, Canada.
  • Gagnon C; Division of Otolaryngology-Head & Neck Surgery, University of Montreal, Montreal, Québec, Canada.
  • Maheu M; Faculty of Medicine, School of Speech Language Pathology and Audiology, University of Montreal, Montreal, Quebec, Canada.
  • Saliba I; Division of Otolaryngology-Head & Neck Surgery, University of Montreal, Montreal, Québec, Canada.
Otolaryngol Head Neck Surg ; 171(2): 494-501, 2024 Aug.
Article in En | MEDLINE | ID: mdl-38415882
ABSTRACT

OBJECTIVES:

To evaluate the sensitivity and the specificity of summating potential (SP)/action potential (AP) area under the curve (AUC) ratio by a transtympanic electrode and a click stimulus (TT-CS), SP/AP AUC ratio by an extratympanic electrode and a click stimulus (ET-CS) and SP amplitude value by a transtympanic electrode and tone burst stimulus (TT-TBS) in regard of Ménière's disease (MD) diagnosis. This is the first study that compares SP amplitude value performed by a TT-TBS and the SP/AP AUC ratio performed by a TT-CS. STUDY

DESIGN:

Retrospective comparative study. SETTINGS Ninety-five patients met the inclusion criteria for electrocochleography (ECochG) testing in a tertiary care center.

METHODS:

The sensitivity and specificity of our different ECochG protocols were calculated in regard of the diagnosis of MD.

RESULTS:

The patients' mean age was 54 years old (female predominance). The sensitivity and the specificity of SP/AP area ratio by a TT-CS were 88.5% and 70.0%, respectively. On the other hand, the sensitivity and specificity for the SP amplitude value by a TT-TBS were 60.0% and 55.6%, respectively. SP/AP area ratio by TT-CS was statistically better than SP amplitude value by TT-TBS to detect MD disease (P = .016). However, no difference was identified between SP/AP area ratio by ET-CS and SP amplitude value by a TT-TBS (P = .573).

CONCLUSION:

SP/AP area ratio by click stimulation has higher sensitivity and specificity to detect MD compared to SP amplitude value by tone burst stimulation. ECochG would be extremely useful in the diagnosis of MD if we use the SP/AP area ratio (sensitivity 88.5%); therefore, it changes the bad reputation of ECochG sensitivity using SP/AP amplitude ratio (sensitivity 51.7%) for the diagnosis of MD.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Audiometry, Evoked Response / Sensitivity and Specificity / Meniere Disease Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Otolaryngol Head Neck Surg Journal subject: OTORRINOLARINGOLOGIA Year: 2024 Document type: Article Affiliation country: Canadá Country of publication: Reino Unido

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Audiometry, Evoked Response / Sensitivity and Specificity / Meniere Disease Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Otolaryngol Head Neck Surg Journal subject: OTORRINOLARINGOLOGIA Year: 2024 Document type: Article Affiliation country: Canadá Country of publication: Reino Unido