A sensitive GC-MS/MS method for the quantification of benzo[a]pyrene tetrol in urine.
Pilz, Fabian; Gärtner, Antonia; Pluym, Nikola; Scherer, Gerhard; Scherer, Max.
Affiliation
  • Pilz F; ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr, 5, 82152, Planegg, Germany.
  • Gärtner A; ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr, 5, 82152, Planegg, Germany.
  • Pluym N; ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr, 5, 82152, Planegg, Germany.
  • Scherer G; ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr, 5, 82152, Planegg, Germany.
  • Scherer M; ABF, Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr, 5, 82152, Planegg, Germany. max.scherer@abf-lab.com.
Anal Bioanal Chem ; 416(12): 2913-2928, 2024 May.
Article in En | MEDLINE | ID: mdl-38459968
ABSTRACT
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous pollutants formed during the incomplete combustion of organic matter such as tobacco. Among these, benzo[a]pyrene (BaP) has been classified as a known carcinogen to humans. It unfolds its effect through metabolic activation to BaP-(7R,8S)-diol-(9S,10R)-epoxide (BPDE), the ultimate carcinogen of BaP. In this article, we describe a simple and highly sensitive GC-NICI-MS/MS method for the quantification of urinary BaP-(7R,8S,9R,10S)-tetrol (( +)-BPT I-1), the hydrolysis product of BPDE. The method was validated and showed excellent results in terms of accuracy, precision, and sensitivity (lower limit of quantification (LLOQ) 50 pg/L). In urine samples derived from users of tobacco/nicotine products and non-users, only consumption of combustible cigarettes was associated with a significant increase in BPT I-1 concentrations (0.023 ± 0.016 nmol/mol creatinine, p < 0.001). Levels of users of potentially reduced-risk products as well as non-users were all below the LLOQ. In addition, the urine levels of six occupationally exposed workers were analyzed and showed the highest overall concentrations of BPT I-1 (844.2 ± 336.7 pg/L). Moreover, comparison with concentrations of 3-hydroxybenzo[a]pyrene (3-OH-BaP), the major detoxification product of BaP oxidation, revealed higher levels of 3-OH-BaP than BPT I-1 in almost all study subjects. Despite the lower levels, BPT I-1 can provide more relevant information on an individual's cancers susceptibility since BPDE is generated by the metabolic activation of BaP. In conclusion, BPT I-1 is a suitable biomarker to distinguish not only cigarette smokers from non-smokers but also from users of potentially reduced-risk products.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tandem Mass Spectrometry / Limit of Detection / Gas Chromatography-Mass Spectrometry Limits: Adult / Humans / Male / Middle aged Language: En Journal: Anal Bioanal Chem Year: 2024 Document type: Article Affiliation country: Alemania Country of publication: Alemania

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tandem Mass Spectrometry / Limit of Detection / Gas Chromatography-Mass Spectrometry Limits: Adult / Humans / Male / Middle aged Language: En Journal: Anal Bioanal Chem Year: 2024 Document type: Article Affiliation country: Alemania Country of publication: Alemania