Your browser doesn't support javascript.
loading
A literature review and expert consensus statement on diagnostics in suspected metal implant allergy.
Thomas, P; Arenberger, P; Bader, R; Bircher, A J; Bruze, M; de Graaf, N; Hartmann, D; Johansen, J D; Jowitz-Heinke, A; Krenn, V; Kurek, M; Odgaard, A; Rustemeyer, T; Summer, B; Thyssen, J P.
Affiliation
  • Thomas P; Department of Dermatology and Allergology, University Hospital, Munich, Germany.
  • Arenberger P; Department of Dermatovenereology, Third Faculty of Medicine, Charles University and University Hospital of Kralovske Vinohrady, Prague, Czech Republic.
  • Bader R; Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
  • Bircher AJ; Department of Dermatology and Allergology, University Hospital and University of Basel, Basel, Switzerland.
  • Bruze M; Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.
  • de Graaf N; Department of Dermatology, VU University Medical Center, Amsterdam, The Netherlands.
  • Hartmann D; Department of Dermatology and Allergology, University Hospital, Munich, Germany.
  • Johansen JD; München Klinik gGmbH, Munich, Germany.
  • Jowitz-Heinke A; Department of Dermatology and Allergy, National Allergy Research Centre, University of Copenhagen, Herlev and Gentofte Hospital, Hellerup, Denmark.
  • Krenn V; Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
  • Kurek M; MVZHZMD Trier GmbH, Trier, Germany.
  • Odgaard A; Hospital MEDICAM, Gryfice, Poland.
  • Rustemeyer T; Department of Orthopaedic Surgery, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark.
  • Summer B; Institute of Clinical Medicine, Copenhagen University, Copenhagen, Denmark.
  • Thyssen JP; Department of Dermatology, VU University Medical Center, Amsterdam, The Netherlands.
J Eur Acad Dermatol Venereol ; 38(8): 1471-1477, 2024 Aug.
Article in En | MEDLINE | ID: mdl-38606660
ABSTRACT

BACKGROUND:

Although rare, allergic reactions to metal implants represent a diagnostic challenge in view of missing guidelines.

OBJECTIVES:

To develop an European expert consensus on characteristics of metal allergy reactions and the utility of various diagnostic tools in suspected metal implant allergy.

METHODS:

A nominal group technique (NGT) was applied to develop consensus statements. Initially an online literature database was created on a secure server to enable a comprehensive information. Twenty-three statements were formulated on potential aspects of metal implant allergy with a focus on diagnostics and grouped into five domains. For the consensus development, the panel of 12 experts initially did refine and reformulate those statements that were ambiguous or had unclear wording. By face-to-face (9/12) or virtual participation (3/12), an anonymous online voting was performed.

RESULTS:

Consensus (≥80% of agreement) was reached in 20/23 statements. The panel agreed that implant allergy despite being rare should be considered in case of persistent unexplained symptoms. It was, however, recommended to allow adequate time for resolution of symptoms associated with healing and integration of an implant. Obtaining questionnaire-aided standardized medical history and standardized scoring of patient outcomes was also considered an important step by all experts There was broad consensus regarding the utility/performance of patch testing with additional late reading. It was recognized that the lymphocyte transformation test (LTT) has to many limitations to be generally recommended. Prior to orthopaedic implant, allergy screening of patients without a history of potential allergy to implant components was not recommended.

CONCLUSIONS:

Using an expert consensus process, statements concerning allergy diagnostics in suspected metal implant allergy were created. Areas of nonconsensus were identified, stressing uncertainty among the experts around topics such as preoperative testing in assumed allergy, histological correlate of periimplant allergy and in vitro testing, which underscores the need for further research.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prostheses and Implants / Consensus / Hypersensitivity / Metals Limits: Humans Language: En Journal: J Eur Acad Dermatol Venereol Journal subject: DERMATOLOGIA / DOENCAS SEXUALMENTE TRANSMISSIVEIS Year: 2024 Document type: Article Affiliation country: Alemania

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prostheses and Implants / Consensus / Hypersensitivity / Metals Limits: Humans Language: En Journal: J Eur Acad Dermatol Venereol Journal subject: DERMATOLOGIA / DOENCAS SEXUALMENTE TRANSMISSIVEIS Year: 2024 Document type: Article Affiliation country: Alemania