Development of dispersive solid phase extraction based on magnetic metal organic framework for the extraction of sunitinib in biological samples and its determination by high performance liquid chromatography-tandem mass spectrometry.
Hassani Nouriyeh, Mandana; Afshar Mogaddam, Mohammad Reza; Nemati, Mahboob; Farajzadeh, Mir Ali; Abbasalizadeh, Aysa; Shahedi Hojghan, Ali.
Affiliation
  • Hassani Nouriyeh M; Student Research Committee, Tabriz University of Medical Sciences, Tabriz, Iran; Pharmaceutics and Food Department, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Afshar Mogaddam MR; Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address: Afsharmogaddam@tbzmed.ac.ir.
  • Nemati M; Pharmaceutics and Food Department, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran; Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address: nematim@tbzmed.ac.ir.
  • Farajzadeh MA; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran; Engineering Faculty, Near East University, 99138 Nicosia, North Cyprus, Mersin 10, Turkey.
  • Abbasalizadeh A; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
  • Shahedi Hojghan A; Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Article in En | MEDLINE | ID: mdl-38636134
ABSTRACT
Herein, a simple, sensitive, and reliable dispersive solid phase extraction was reported for the efficient extraction of sunitinib from biological samples. To facilitate the extraction of the desired analyte from urine and plasma samples, magnetic MIL-101Cr (NH2) @SiO2 @ NiFe2O4 was synthesized by a hydrothermal method and applied as an effective sorbent during the extraction process. After adsorption of the drug using 10 mg of MIL-101Cr (NH2) @ SiO2 @ NiFe2O4 nanoparticles through vortexing (1 min), the sorbent was separatedfrom the sample solution using a magnet. To eluate the drug, the sorbent containing the sunitinib was contacted with 100 µL dimethylformamide. The eluent was analyzed by high performance liquid chromatography-tandem mass spectrometry. Reasonable validation data consisting of low limits of detection (0.14, 0.35, and 0.70 ng mL-1 in deionized water, plasma, and urine) and quantification (0.48, 1.2, and 2.4 ng mL-1 in deionized water, plasma, and urine, respectively), a wide linear range of the calibration curve (0.48-200, 1.2-200, and 2.4-100 ng mL-1 in deionized water, plasma, and urine, respectively) good extraction recovery (76 %), and low relative standard deviations for inter- and intra-day precisions (6.9 %) were obtained by the method. Eventually, the proposed procedure was effectively implemented on both plasma and urine samples, yielding successful outcomes.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tandem Mass Spectrometry / Solid Phase Extraction / Limit of Detection / Metal-Organic Frameworks / Sunitinib Limits: Humans Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Affiliation country: Irán Country of publication: Países Bajos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tandem Mass Spectrometry / Solid Phase Extraction / Limit of Detection / Metal-Organic Frameworks / Sunitinib Limits: Humans Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Affiliation country: Irán Country of publication: Países Bajos