Your browser doesn't support javascript.
loading
Assessment of the Cyclic Fatigue Performance of the Novel Protaper Ultimate File System Used in Different Kinematics: An In Vitro Study.
Diaconu, Cezar Tiberiu; Diaconu, Anca Elena; Tuculina, Mihaela Jana; Mihai, Laurența Lelia; Gheorghița, Mircea; Gheorghița, Lelia Mihaela; Marașescu, Petre; Gliga, Alexandru; Diaconu, Oana Andreea.
Affiliation
  • Diaconu CT; Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Diaconu AE; Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Tuculina MJ; Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Mihai LL; Faculty of Dental Medicine, University Titu Maiorescu of Bucharest, 031593 Bucharest, Romania.
  • Gheorghița M; Faculty of Dental Medicine, Department of Oral and Maxillofacial Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Gheorghița LM; Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Marașescu P; Faculty of Dental Medicine, Department of Dental Prothesis Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
  • Gliga A; Faculty of Dental Medicine, Department of Operative Dentistry, "Carol Davila" University of Medicine and Pharmacy, 050474 Bucharest, Romania.
  • Diaconu OA; Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
J Funct Biomater ; 15(4)2024 Mar 29.
Article in En | MEDLINE | ID: mdl-38667542
ABSTRACT
This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research.

Methods:

A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student's t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM.

Conclusions:

The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.