Your browser doesn't support javascript.
loading
Use of a novel device for intraoperative wire management during fenestrated endovascular type 4 thoracoabdominal aortic aneurysm repair.
Li, Richard L; Shapiro, Jake; Reichard, Adam; Broering, Mark; Recht, Matthew; Muck, Patrick.
Affiliation
  • Li RL; Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign.
  • Shapiro J; Division of Vascular Surgery John J Cranley Vascular Laboratory, Good Samaritan Hospital Trihealth inc. Cincinnati, 375 Dixmyth Ave, Good Samaritan Hospital, Dept Graduate Medical Education, Cincinnati, OH 45233, USA.
  • Reichard A; Division of Vascular Surgery John J Cranley Vascular Laboratory, Good Samaritan Hospital Trihealth inc. Cincinnati, 375 Dixmyth Ave, Good Samaritan Hospital, Dept Graduate Medical Education, Cincinnati, OH 45233, USA.
  • Broering M; Division of Vascular Surgery John J Cranley Vascular Laboratory, Good Samaritan Hospital Trihealth inc. Cincinnati, 375 Dixmyth Ave, Good Samaritan Hospital, Dept Graduate Medical Education, Cincinnati, OH 45233, USA.
  • Recht M; Division of Vascular Surgery John J Cranley Vascular Laboratory, Good Samaritan Hospital Trihealth inc. Cincinnati, 375 Dixmyth Ave, Good Samaritan Hospital, Dept Graduate Medical Education, Cincinnati, OH 45233, USA.
  • Muck P; Division of Vascular Surgery John J Cranley Vascular Laboratory, Good Samaritan Hospital Trihealth inc. Cincinnati, 375 Dixmyth Ave, Good Samaritan Hospital, Dept Graduate Medical Education, Cincinnati, OH 45233, USA.
Radiol Case Rep ; 19(7): 2868-2873, 2024 Jul.
Article in En | MEDLINE | ID: mdl-38706815
ABSTRACT
Endovascular procedures are minimally invasive approaches to treat conditions affecting blood vessels without the need for large incisions. The benefits are less blood loss and faster recovery. One condition commonly treated endovascularly is aortic aneurysmal disease often secondary to atherosclerosis or chronic hypertension. As endovascular aneurysm repair becomes increasingly complex and sophisticated, the intraoperative organization and management of wires from multiple access sites becomes paramount. Often, the physician selects visceral or great vessels for delivery of stent grafts to maintain vessel patency. Loss of wire in critical target vessels and wire contamination pose significant patient risks. WireWatch (BioTex Inc. Houston, Texas, USA) is a novel device designed for intraoperative wire management to improve surgical field organization, provide wire stabilization, and prevent dropped wires. This case describes its use in a 73-year-old female undergoing a fenestrated endovascular aneurysm repair of 5.6 cm types IV thoracoabdominal aortic aneurysm.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Radiol Case Rep Year: 2024 Document type: Article Country of publication: Países Bajos

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Radiol Case Rep Year: 2024 Document type: Article Country of publication: Países Bajos