Improving Automated Hemorrhage Detection at Sparse-View CT via U-Net-based Artifact Reduction.
Thalhammer, Johannes; Schultheiß, Manuel; Dorosti, Tina; Lasser, Tobias; Pfeiffer, Franz; Pfeiffer, Daniela; Schaff, Florian.
Affiliation
  • Thalhammer J; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Schultheiß M; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Dorosti T; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Lasser T; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Pfeiffer F; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Pfeiffer D; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
  • Schaff F; From the Department of Physics, School of Natural Sciences (J.T., M.S., T.D., F.P., D.P., F.S.), Munich Institute of Biomedical Engineering (J.T., M.S., T.D., T.L., F.P., D.P., F.S.), Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar (J.T., M.S., T.D
Radiol Artif Intell ; 6(4): e230275, 2024 Jul.
Article in En | MEDLINE | ID: mdl-38717293
ABSTRACT
Purpose To explore the potential benefits of deep learning-based artifact reduction in sparse-view cranial CT scans and its impact on automated hemorrhage detection. Materials and Methods In this retrospective study, a U-Net was trained for artifact reduction on simulated sparse-view cranial CT scans in 3000 patients, obtained from a public dataset and reconstructed with varying sparse-view levels. Additionally, EfficientNet-B2 was trained on full-view CT data from 17 545 patients for automated hemorrhage detection. Detection performance was evaluated using the area under the receiver operating characteristic curve (AUC), with differences assessed using the DeLong test, along with confusion matrices. A total variation (TV) postprocessing approach, commonly applied to sparse-view CT, served as the basis for comparison. A Bonferroni-corrected significance level of .001/6 = .00017 was used to accommodate for multiple hypotheses testing. Results Images with U-Net postprocessing were better than unprocessed and TV-processed images with respect to image quality and automated hemorrhage detection. With U-Net postprocessing, the number of views could be reduced from 4096 (AUC 0.97 [95% CI 0.97, 0.98]) to 512 (0.97 [95% CI 0.97, 0.98], P < .00017) and to 256 views (0.97 [95% CI 0.96, 0.97], P < .00017) with a minimal decrease in hemorrhage detection performance. This was accompanied by mean structural similarity index measure increases of 0.0210 (95% CI 0.0210, 0.0211) and 0.0560 (95% CI 0.0559, 0.0560) relative to unprocessed images. Conclusion U-Net-based artifact reduction substantially enhanced automated hemorrhage detection in sparse-view cranial CT scans. Keywords CT, Head/Neck, Hemorrhage, Diagnosis, Supervised Learning Supplemental material is available for this article. © RSNA, 2024.