Your browser doesn't support javascript.
loading
Conduction disorders following transcatheter aortic valve replacement using acurate Neo2 transcatheter heart valve: A propensity matched analysis.
Loewenstein, Itamar; Finkelstein, Ariel; Banai, Shmuel; Halkin, Amir; Konigstein, Maayan; Ben-Shoshan, Jeremy; Arbel, Yaron; Barbash, Israel; Segev, Amit; David, Planner; Elbaz-Greener, Gabby; Assa-Vaknin, Hana; Kornowski, Ran; Dvir, Danny; Asher, Elad; Steinvil, Arie.
Affiliation
  • Loewenstein I; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Finkelstein A; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Banai S; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Halkin A; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Konigstein M; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Ben-Shoshan J; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Arbel Y; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Barbash I; Leviev Heart Center, Chaim Sheba Medical Center, Ramat Gan, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Segev A; Leviev Heart Center, Chaim Sheba Medical Center, Ramat Gan, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • David P; Cardiology Department, Hadassah Medical Center, Jerusalem, Israel; Affiliated to the Hebrew University of Jerusalem, Jerusalem, Israel.
  • Elbaz-Greener G; Cardiology Department, Hadassah Medical Center, Jerusalem, Israel; Affiliated to the Hebrew University of Jerusalem, Jerusalem, Israel.
  • Assa-Vaknin H; Cardiology Department, Rabin Medical Center, Petach Tikva, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Kornowski R; Cardiology Department, Rabin Medical Center, Petach Tikva, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Dvir D; Cardiology Department, Sha'arei Zedek Medical Center, Jerusalem, Israel; Affiliated to the Hebrew University of Jerusalem, Jerusalem, Israel.
  • Asher E; Cardiology Department, Sha'arei Zedek Medical Center, Jerusalem, Israel; Affiliated to the Hebrew University of Jerusalem, Jerusalem, Israel.
  • Steinvil A; Cardiology Department, Tel Aviv Sourasky Medical Center, Israel; Affiliated to Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel. Electronic address: arikst@tlvmc.gov.il.
Article in En | MEDLINE | ID: mdl-38719632
ABSTRACT

BACKGROUND:

The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves.

METHODS:

A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics.

RESULTS:

Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL.

CONCLUSIONS:

In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cardiovasc Revasc Med Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Israel

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cardiovasc Revasc Med Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Israel