Your browser doesn't support javascript.
loading
Intraoperative live measurement of femoral head size for acetabular cup sizing: simple, accurate, and green!
Assi, Chahine; Boulos, Karl; Haykal, Emil; Caton, Jacques; Prudhon, Jean Louis; Yammine, Kaissar.
Affiliation
  • Assi C; Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Lebanese American University School of Medicine, Beirut, Lebanon.
  • Boulos K; Center for Evidence-Based Anatomy, Sport & Orthopedics Research, Beirut, Lebanon.
  • Haykal E; Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Lebanese American University School of Medicine, Beirut, Lebanon.
  • Caton J; Center for Evidence-Based Anatomy, Sport & Orthopedics Research, Beirut, Lebanon.
  • Prudhon JL; Department of Orthopedic Surgery, Lebanese American University Medical Center-Rizk Hospital, Lebanese American University School of Medicine, Beirut, Lebanon.
  • Yammine K; Institut de Chirurgie Orthopedique, Lyon, France.
Int Orthop ; 48(8): 2025-2031, 2024 Aug.
Article in En | MEDLINE | ID: mdl-38748096
ABSTRACT

PURPOSE:

Templating is the first step in achieving a successful total hip arthroplasty. We hypothesize that native head size is highly correlated with implanted cup size. Therefore, the purpose of this study is to look for a correlation between sizes of the intra-operative measurement of the femoral head and the implanted cup.

METHODS:

This is a monocentric observational study conducted from December 2018 till January 2023. All patients admitted for a primary total hip arthroplasty were included and retrospectively reviewed. Intra-operative femoral head measurement, radiographic femoral head diameter, templated (planned) cup size, and definitive implanted cup size were recorded.

RESULTS:

The sample included 154 patients (85 female and 69 males) with a mean age of 66.2 ± 10.4 years. There were 157 THA cases; 82 on the right side and 75 on the left side. The native head size and acetate template on digital radiographs were the most significantly positively correlated with cup size (P < 0.0001) while the radiological head size was significantly negatively correlated with cup size (P = 0.009). The implanted cup was on average 2 ± 2 mm bigger than the native head size measured intra-operatively.

CONCLUSION:

The native femoral head diameter measured intra-operatively is a simple and reliable tool to help the surgeons choose the proper size of the acetabular cup, preventing complications during surgery hence optimizing results post operatively. This technique would contribute to a more ecofriendly orthopaedic reconstructive surgery.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Femur Head / Hip Prosthesis / Acetabulum Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Int Orthop Year: 2024 Document type: Article Affiliation country: Líbano

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Femur Head / Hip Prosthesis / Acetabulum Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Int Orthop Year: 2024 Document type: Article Affiliation country: Líbano