Your browser doesn't support javascript.
loading
Validity of luminometry and bacteriological tests for diagnosing intramammary infection at dry-off in dairy cows.
Denis-Robichaud, J; Barbeau-Grégoire, N; Gauthier, M-L; Dufour, S; Roy, J-P; Buczinski, S; Dubuc, J.
Affiliation
  • Denis-Robichaud J; Independent researcher, Amqui, Québec, Canada G5J 2N5.
  • Barbeau-Grégoire N; Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada J2S 2M2.
  • Gauthier ML; Ministère de l'Agriculture, des Pêcheries et de l'Alimentation du Québec, Saint-Hyacinthe, Québec, Canada, J2S 2M2.
  • Dufour S; Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada J2S 2M2; Op+lait research group, Saint-Hyacinthe, Québec, Canada, J2S 2M2.
  • Roy JP; Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada J2S 2M2; Op+lait research group, Saint-Hyacinthe, Québec, Canada, J2S 2M2.
  • Buczinski S; Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada J2S 2M2; Op+lait research group, Saint-Hyacinthe, Québec, Canada, J2S 2M2.
  • Dubuc J; Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada J2S 2M2; Op+lait research group, Saint-Hyacinthe, Québec, Canada, J2S 2M2. Electronic address: jocelyn.dubuc@umontreal.ca.
J Dairy Sci ; 107(9): 7221-7229, 2024 Sep.
Article in En | MEDLINE | ID: mdl-38788849
ABSTRACT
The objective of this cross-sectional study was to estimate the validity of laboratory culture, Petrifilm and Tri-Plate on-farm culture systems, as well as luminometry to correctly identify IMI at dry-off in dairy cows, considering all tests to be imperfect. From September 2020 until December 2021, we collected composite milk samples from cows before dry-off and divided them into 4 aliquots for luminometry, Petrifilm (aerobic count), Tri-Plate, and laboratory culture tests. We assessed multiple thresholds of relative light units (RLU) for luminometry, and we used thresholds of ≥100 cfu/mL for the laboratory culture, ≥50 cfu/mL for Petrifilm, and ≥1 cfu for Tri-Plate tests. We fitted Bayesian latent class analysis models to estimate the sensitivity (Se) and specificity (Sp) for each test to identify IMI, with 95% credibility interval (BCI). Using different prevalence measures (0.30, 0.50, and 0.70), we calculated the predictive values (PV) and misclassification cost terms (MCT) at different false negative-to-false-positive ratios (FNFP). A total of 333 cows were enrolled in the study from one commercial Holstein herd. The validity of the luminometry was poor for all thresholds, with an Se of 0.51 (95% BCI = 0.43-0.59) and Sp of 0.38 (95% BCI = 0.26-0.50) when using a threshold of ≥150 RLU. The laboratory culture had an Se of 0.93 (95% BCI = 0.85-0.98) and Sp of 0.69 (95% BCI = 0.49-0.89); the Petrifilm had an Se of 0.91 (95% BCI = 0.80-0.98) and Sp of 0.71 (95% BCI = 0.51-0.90); and the Tri-Plate had an Se of 0.65 (95% BCI = 0.53-0.82) and Sp of 0.85 (95% BCI = 0.66-0.97). Bacteriological tests had good PV, with comparable positive PV for all 3 tests, but lower negative PV for the Tri-Plate compared with the laboratory culture and the Petrifilm. For a prevalence of IMI of 0.30, all 3 tests had similar MCT, but for prevalence of 0.50 and 0.70, the Tri-Plate had higher MCT in scenarios where leaving a cow with IMI untreated is considered to have greater detrimental effects than treating a healthy cow (i.e., FNFP of 31). Our results showed that the bacteriological tests have adequate validity to diagnose IMI at dry-off, but luminometry does not. We concluded that although luminometry is not useful to identify IMI at dry-off, the Petrifilm and Tri-Plate tests performed similarly to laboratory culture, depending on the prevalence and importance of the FP and FN results.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bacteriological Techniques / Animal Husbandry / Mastitis, Bovine Limits: Animals Language: En Journal: J Dairy Sci Year: 2024 Document type: Article Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bacteriological Techniques / Animal Husbandry / Mastitis, Bovine Limits: Animals Language: En Journal: J Dairy Sci Year: 2024 Document type: Article Country of publication: Estados Unidos