ABSTRACT
An electroceutical is a medical device that uses electrical signals to control biological functions. It can be inserted into the human body as an implant and has several crucial advantages over conventional medicines for certain diseases. This research develops a new vagus nerve simulation (VNS) electroceutical through an innovative approach to overcome the communication limitations of existing devices. A phased array antenna with a better communication performance was developed and applied to the electroceutical prototype. In order to effectively respond to changes in communication signals, we developed the steering algorithm and firmware, and designed the smart communication protocol that operates at a low power that is safe for the patients. This protocol is intended to improve a communication sensitivity related to the transmission and reception distance. Based on this technical approach, the heightened effectiveness and safety of the prototype have been ascertained, with the actual clinical tests using live animals. We confirmed the signal attenuation performance to be excellent, and a smooth communication was achieved even at a distance of 7 m. The prototype showed a much wider communication range than any other existing products. Through this, it is conceivable that various problems due to space constraints can be resolved, hence presenting many benefits to the patients whose last resort to the disease is the VNS electroceutical.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Vagus Nerve / Algorithms Limits: Animals / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Vagus Nerve / Algorithms Limits: Animals / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza