Your browser doesn't support javascript.
loading
Evaluating pelvic tilt using the pelvic antero-posterior radiographs: A novel method.
Chai, Yuan; Boudali, A Mounir; Veltman, Ewout S; Farey, John E; Walter, William L.
Affiliation
  • Chai Y; Sydney Muskuloskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia.
  • Boudali AM; Institute of Future Health, South China University of Technology, Guangzhou, China.
  • Veltman ES; Sydney Muskuloskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia.
  • Farey JE; Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
  • Walter WL; Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
J Orthop Res ; 42(10): 2318-2326, 2024 Oct.
Article in En | MEDLINE | ID: mdl-38814154
ABSTRACT
Pelvic tilt (PT) is an important parameter for orthopedic surgeries involving hip and spine, typically determined from sagittal pelvic radiographs. However, various challenges can compromise the feasibility of measurement from sagittal imaging, including obscured landmarks, anatomical variations, hardware interference, and limited medical resources. Addressing these challenges and with the aim of reducing radiation exposure to patients, our study developed a novel method to estimate PT from antero-posterior (AP) radiographs, using vertical distances from the pelvic outlet and obturator foramen. We correlated these measurements with PT, defined both anatomically (anterior pelvic plane, PTa) and mechanically (centers of femoral heads and sacral plate, PTm). The study explored creating linear, exponential, and multivariate regression models based on twelve 3D CT-derived pelvic models (six men, six women), simulating AP radiograph projections with controlled PTs. We then validated these models against 105 pairs of patient stereoradiographs. Statistical analysis revealed that combined exponential-linear models yielded the most accurate results, with Pearson correlation coefficients of 0.75 for PTa and 0.77 for PTm, and mean absolute errors of 3.7° ± 2.6° for PTa and 4.5° ± 3.4° for PTm, showing excellent measurement reliability (all ICCs > 0.9) without significant gender discrepancies. In conclusion, this study presents a validated, simple, and accessible method for estimating PT using AP radiograph parameters, supported by the Supporting Information S1 Excel Tool, showing great potential for clinical application in hip and spine procedures.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pelvic Bones Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Res Year: 2024 Document type: Article Affiliation country: Australia Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pelvic Bones Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Res Year: 2024 Document type: Article Affiliation country: Australia Country of publication: Estados Unidos