Your browser doesn't support javascript.
loading
Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework.
Muhsin, Saja Ali; Mohammed, Enas Kareem; Bander, Khalid.
Affiliation
  • Muhsin SA; Middle Technical University.
  • Mohammed EK; Middle Technical University, Institute of Medical Technology, Baghdad, Iraq.
  • Bander K; Middle Technical University, College of Health and Medical Techniques, Baghdad, Iraq.
J Long Term Eff Med Implants ; 34(4): 33-47, 2024.
Article in En | MEDLINE | ID: mdl-38842231
ABSTRACT
This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Dental Prosthesis, Implant-Supported / Finite Element Analysis / Denture, Partial, Fixed Limits: Humans Language: En Journal: J Long Term Eff Med Implants Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Dental Prosthesis, Implant-Supported / Finite Element Analysis / Denture, Partial, Fixed Limits: Humans Language: En Journal: J Long Term Eff Med Implants Year: 2024 Document type: Article
...