Your browser doesn't support javascript.
loading
Highly stabilized fiber Bragg grating accelerometer based on cross-type diaphragm.
Opt Express ; 32(12): 21447-21458, 2024 Jun 03.
Article in En | MEDLINE | ID: mdl-38859498
ABSTRACT
A fiber Bragg grating (FBG) accelerometer based on cross-type diaphragm was proposed and designed, in which the cross-beam acts as a spring element. To balance the sensitivity and stability, the accelerometer structure was optimized. The experimental results show that the designed device has a resonant frequency of 556 Hz with a considerable wide frequency bandwidth of up to 200 Hz, which is consistent with the simulation. The sensitivity of the device is 12.35 pm/g@100 Hz with a linear correlation coefficient of 0.99936. The proposed FBG accelerometer has simple structure and strong anti-interference capability with a maximal cross-error less than 3.26%, which can be used for mechanical structural health monitoring.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Opt Express Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Country of publication: Estados Unidos